7) OPERATION
1) Connect the welding and return cable to the terminals at the bottom of the front panel.
2) Turn the circuit switch to "1" there by connecting the rectifier to the mains.
3) Make sure that the air inlets are not blocked.
4) Adjust desired welding current setting with the crank at the front panel.
Note
:
The welding parameters values basically depend on the material and
electrode diameter used, on the thickness of the piece of the to-be-weld piece and
the welding position.
8 MAINTENANCE AND SERVICE
9 SET OF CABLES
The rectifiers require a minimum of maintenance. Under normal conditions, it is sufficient to blow the
rectifier clean with dry compressed air with reduced pressure once a year. If used in dusty and dirty areas, it
must be cleaned more often.
Electrode holder and work clamp - 0400257
10 OPTIONAL
Trolley - 0401772
Volt/Amp kit for Origo Arc 426/456 - 0402223
TM
19
Volt/Amp
Trolley