INTRODUCTION
The OCF 2 cooling unit comes in four versions, designed for use with LTN/LTR
160/200/255, DTE 200/255, LTS160/250, and semi--automated power sources.
3.1
Equipment
Check the coolant level before use.
If necessary, top up with water and glycol.
S
OCF 2L and OCF 2D are equipped with a transformer which is fed by the
welding power source.
Can be supplied with a flow monitor (0467 118 001).
S
OCF 2M has relays to allow supply via the welding power source.
S
OCF 2A is fitted with an earthed plug complying with Swedish regulations.
Can be stood on edge if it is fitted with feet (4 off. 0467 695 001).
4
TECHNICAL DATA
Model
OCF 2L
OCF 2D*)
OCF 2M
OCF 2A
Voltage
400 V
400 V
230 V
230 V
Power consumption
250 W
250 W
250 W
250 W
Cooling effect
2000 W
2000 W
2000 W
2000 W
Power source
LTN/LTR
200,255
DTE 200/255
LTS 160/250
LTN/LTR 160,
Automated.
Drive
Internal from
welding power
source
Internal from
welding power
source
Internal from
welding power
source
Internal from
power supply
Coolant
Water/Glycol
Water/Glycol
Water/Glycol
Water/Glycol
Coolant capacity
5 L
5 L
5 L
5 L
Max. pressure
3 bar
3 bar
3 bar
3 bar
Max. water flow
4 l/min
4 l/min
4 l/min
4 l/min
Air flow
200 m3/h
200 m3/h
200 m3/h
200 m3/h
Fuse, slow
1.25 A
1.25 A
Enclosure class
IP 23
IP 23
IP 23
IP 23
Weight
22 kg
25 kg
19,5 kg
19,5 kg
Dimensions
470x260x190
500x290x190
470x260x190
470x260x190
*) OCF 2D is a special version with larger external dimensions, but otherwise the same as OCF 2L.
Enclosure class
The
IP
code indicates the enclosure class, i. e. the degree of protection against penetration by solid
objects or water. Equipment marked
IP 23
is designed for indoor and outdoor use.
GB