4 INSTALLATION
0558 012 634
- 13 -
© ESAB AB 2016
4.8
Supply connections
CAUTION!
Turn off the power source and the wire feeder.
The MobileFeed 301 AVS can be used with either DC Electrode Positive (DCEP) or DC
Electrode Negative (DCEN) polarity without modifications.
1.
Connect the welding cable (1) from the power source to the weld cable lug connection
extending from the rear of the MobileFeed 301 AVS feeder.
a) Positive terminal for gas shielded flux cored or solid wires.
b) Negative terminal for most gasless self-shielded cored wires.
WARNING!
Make sure that the welding cables are correctly insulated before
applying power to the power source. Uninsulated cable and parts can
arc when contacting a grounded surface. The arc may damage eyes
or start a fire. Body contact with an uninsulated weld cable connector,
or uncovered conductor can cause shock and severe injury, possibly
fatally.
2.
Connect a second welding cable (2) between the opposite polarity output connection
on the power source and the work piece.
3.
Connect the wire feeder work lead/voltage pick-up cable clip (3) to the work piece.
4.
If gas shielded wire is used, connect the inlet gas hose to the gas inlet connections on
the rear of the feeder.
5.
Make sure that all hose and cable connections are tight.
6.
Turn on the power source and close the contactor if the power source is equipped with
an output contactor control switch. Open circuit voltage must be present to operate the
wire feeder.
Содержание MobileFeed 301 AVS
Страница 1: ...Instruction manual 0558 012 634 GB 20160229 Valid for serial no WxxK533xxxx MobileFeed 301 AVS...
Страница 2: ......
Страница 27: ...WIRING DIAGRAM 0558 012 634 27 ESAB AB 2016 WIRING DIAGRAM...
Страница 30: ...WEAR PARTS CE PRODUCTS 0558 012 634 30 ESAB AB 2016...
Страница 33: ...ACCESSORIES 0558 012 634 33 ESAB AB 2016...