21
SECTION 3 INSTALLATION
3.10 INSTALLING OPTIONAL DIGITAL METER
a. Remove the top blank-cover plate from the upper-
right front panel of the power supply -- save the four
mounting screws.
b. Locate the harness-connected 10-pin plastic plug,
PL1, inside the mounting cavity. This plug does
not
have a jumper plug connected to it.
c. Connect the 10-pin plug into the matching recep-
tacle on the rear of the optional meter module.
d. Install the meter module in place of the blank-
panel removed in Step a., using the same four
screws that you saved..