15
4.TECHNICAL DATA
Mains voltage
400V-415V 3~ 50Hz
Mains cable cross-section
4x4mm
2
Mains fuse
25 A delayed
Rated power consumption
18,8 kVA
Rated primary current @ P35%
26 A
Rated welding current
Duty cycle* 35%
400 A
Duty cycle* 100%
237 A
Welding current range
30A
÷
400A
Open circuit voltage
14
÷
47V
Dimensions
length
width
height
1100
630
845
Weight
215 kg
Working flow of cooling liquid at pressure of 2,5 bar
1 dm
3
/min (60l/h)
Selection of cooling liquid depending on ambient temperature
-
Distilled
water
-
Solution of 30% Antifreeze C 70% distilled water
from 0
°
C to +40
°
C
from -10
°
C
Tank capacity
6 dm
3
*Duty cycle is based on 10-minute period. Duty cycle 30% means that after 3 minutes of unit operation, 7
minutes break is required. Duty cycle 100% means that unit can operate continuously.
Warning:
The unit is characterised by the following :
-
Enclosure class IP 23 indicates that unit is designed for indoor and outdoor use.
-
Application class S means that the unit is designed for use in areas of elevated electric hazard.
5. LOAD CHARACTERISTIC
0
5
10
15
20
25
30
35
40
45
50
0
50
100
150
200
250
300
350
400
450
500
I2(A)
U2(
V
)
Содержание LKB 400W
Страница 1: ...LKB 400W WELDING RECTIFIER Service manual 0349 300 020 01 01 24 ...
Страница 5: ...5 LKB 400W 400V ...
Страница 6: ...6 2 COMPONENT POSITIONS CIRCUIT BOARD LA07 A1 ...
Страница 7: ...7 DIAGRAM LA07 A1 ...
Страница 9: ...9 3 COMPONENT POSITIONS CIRCUIT BOARD LKC31 A2 ...
Страница 22: ......
Страница 25: ...25 ...