background image

Instruction manual

0449 507 101 GB 20170901

Valid for: serial no. 126-xxx-xxxx

LAF 1601 / LAF 1601M

Содержание LAF 1601

Страница 1: ...Instruction manual 0449 507 101 GB 20170901 Valid for serial no 126 xxx xxxx LAF 1601 LAF 1601M ...

Страница 2: ......

Страница 3: ...STALLATION 9 4 1 Location 9 4 2 Connections 10 5 OPERATION 12 5 1 Controls 12 6 MAINTENANCE 13 6 1 Cleaning 13 6 1 1 Welding power source 13 6 1 2 Contactor 13 7 ORDERING SPARE PARTS 14 DIAGRAM 15 CONNECTION INSTRUCTION 17 ORDERING NUMBERS 19 Rights reserved to alter specifications without notice ...

Страница 4: ...cautions welding and cutting or other applicable operation of the equipment 2 The operator must ensure that no unauthorised person is stationed within the working area of the equipment when it is started up no one is unprotected when the arc is struck or work is started with the equipment 3 The workplace must be suitable for the purpose be free from drafts 4 Personal safety equipment Always wear r...

Страница 5: ...r eyes and body Use the correct welding screen and filter lens and wear protective clothing Protect bystanders with suitable screens or curtains FIRE HAZARD Sparks spatter can cause fire Make sure therefore that there are no inflammable materials nearby NOISE Excessive noise can damage hearing Protect your ears Use earmuffs or other hearing protection Warn bystanders of the risk MALFUNCTION Call f...

Страница 6: ...d or electronic equipment that has reached the end of its life must be disposed of at a recycling facility As the person responsible for the equipment it is your responsibility to obtain information on approved collection stations For further information contact the nearest ESAB dealer ESAB has an assortment of welding accessories and personal protection equipment for purchase For ordering informa...

Страница 7: ...r high efficiency mechanical submerged arc welding SAW The welding power sources are fan cooled and are monitored by a thermal cutout against overload When the thermal cutout is deployed the yellow lamp on the front panel illuminates automatically The reset is carried out automatically when the temperature has decreased to a permitted level ...

Страница 8: ... Setting range 100 1600 A 24 44 V 100 1600 A 24 44 V No load voltage 56 V 56 V No load power 230 W 230 W Efficiency 88 88 Power factor at maximum current 0 84 0 84 Apparent power I2 at maximum current 95 6 kVA 87 5 kVA Active power I2 at maximum current 80 kW 80 kW Continual sound pressure at no load 70 dB A 70 dB A Weight 585 kg 585 kg Dimensions L x W x H 774 x 598 x 1430 mm 774 x 598 x 1430 mm ...

Страница 9: ...dance or the required minimum supply capacity at the interface point to the public grid may apply for some types of equipment see TECHNICAL DATA chapter In this case it is the responsibility of the installer or user of the equipment to ensure by consultation with the distrubution network operator if necessary that the equipment may be connected 4 1 Location WARNING Secure the equipment particularl...

Страница 10: ...he control box to the 28 pin connector 2 on the inside of the welding power source Connect the 1 pin measuring cable 4 for measuring the arc voltage to the return cable welding head Connect a suitable welding and return cable in the connectors 3 marked and on the front of the welding power source Fit the side front plates Mains connection LAF 1601 3 50 Hz 3 60 Hz Mains voltage 400 415 V 500 V 440 ...

Страница 11: ...01 11 ESAB AB 2017 NOTE The mains cable areas and fuse sizes as shown above are in accordance with Swedish regulations For other regions supply cables must be suitable for the application and meet local and national regulations ...

Страница 12: ...nt panel contains 1 Main circuit breaker for switching the mains voltage and the fan on and off in the welding power source Position 1 On Position 0 Off 2 The indicator lamp white illuminates when the main switch is switched on 3 Indicator lamp for overheating yellow The indicator lamp illuminates when the thermal cutout is deployed due to excess temperature in the welding power source The indicat...

Страница 13: ... air inlets or outlets will lead to overheating Clean the welding power source as necessary Dry compressed air is recommended for the purpose 6 1 2 Contactor WARNING Never use compressed air to clean the contactor without first taking it apart completely NOTE To ensure the reliable operation of the contactor the magnetic parts must be kept clean If the contactor has to be cleaned it must be taken ...

Страница 14: ...d European standards EN 60974 1 and EN 60974 10 It is the obligation of the service unit which has carried out the service or repair work to make sure that the product still conforms to the said standard Spare parts and wear parts can be ordered through your nearest ESAB dealer see the back cover of this document When ordering please state product type serial number designation and spare part numb...

Страница 15: ...DIAGRAM 0449 507 101 15 ESAB AB 2017 DIAGRAM Valid for serial no 126 xxx xxxx ...

Страница 16: ...DIAGRAM 0449 507 101 16 ESAB AB 2017 ...

Страница 17: ...CONNECTION INSTRUCTION 0449 507 101 17 ESAB AB 2017 CONNECTION INSTRUCTION LAF 1601 ...

Страница 18: ...CONNECTION INSTRUCTION 0449 507 101 18 ESAB AB 2017 LAF 1601M ...

Страница 19: ...ng no Denomination Notes 0460 515 880 Welding power source LAF 1601 0460 515 881 Welding power source LAF 1601M 0459 839 059 Spare parts list LAF 1601 LAF 1601M The spare parts list is published in a separate document that can be downloaded from the Internet www esab com ...

Страница 20: ...e Henares MADRID Tel 34 91 878 3600 Fax 34 91 802 3461 SWEDEN ESAB Sverige AB Gothenburg Tel 46 31 50 95 00 Fax 46 31 50 92 22 ESAB International AB Gothenburg Tel 46 31 50 90 00 Fax 46 31 50 93 60 SWITZERLAND ESAB Europe GmbH Baar Tel 41 1 741 25 25 Fax 41 1 740 30 55 UKRAINE ESAB Ukraine LLC Kiev Tel 38 044 501 23 24 Fax 38 044 575 21 88 North and South America ARGENTINA CONARCO Buenos Aires Tel...