FAULT FINDING
0464 523 010
- 18 -
© ESAB AB 2016
1. Check the voltage over the smothing caps on PCB1 and PCB10.
2. Check that PCB5 is supplied with 24 V DC, it is indicated by the red diode on the board.
3. Turn off the power source and wait for five minutes.
4. Check the spark gap on PCB5 with a feeler gauge. The gap shall be 0.5 - 0.6 mm.