Revision OR
05 \ 2003
0558004303 Printed in U.S.A.
A
H
G
F
N
K
J
E
D
C
B
L
M
I
FACE VIEW
Make sure all primary power to Power Source is disconnected before installation of these plugs.
WARNING
INSTRUCTIONS for
This remote control is designed for use with any
power source that employs a single (common) cur-
rent and contactor control 14-pin Amphenol recep-
tacle. It contains a potentiometer which controls the
current output when the Panel/Remote Switch (PRS)
on the power source is placed in the "Remote"
position. This remote control also consists of a
switch when the PRS is placed in the "Remote"
position. Both the potentiometer and switch are
operated when the FC-5C pedal is depressed. See
the schematic diagram in your respective power
source instruction literature.
Interconnection of these functions to the main power
source is provided by a single mating 30-ft. cable/
plug assembly provided.
By depressing the foot pedal, the weld start sequence
circuit will energize, and the welding current will in-
crease or decrease semi-linearly within the range pre-
set on the power source "Current" control potentiom-
eter.
To use the remote control, proceed as follows:
1. Plug the FC-5C control cable into current/contactor
control receptacle on the power source.
2. Set the Remote/Panel toggle switch to the Remote
position.
3. Set the Current Control on the power source panel to
the maximum current range to be used.
4. Depress foot pedal as desired to weld.
FC-5C FOOT OPERATED
REMOTE CURRENT AND CONTACTOR CONTROL
!
ESAB
ESAB Welding & Cutting Products
PO Box 100545, Florence SC 29501-0545
BLACK
RED
WHITE
BROWN
BLUE
P1
E
F
G
D
B
A
R9
SCHEMATIC DIAGRAM
FC-5C Foot Control Assembly (30 ft.)
ESAB P/N 0558004234
12 / 2004
(SW Closed)
Treadle In Down Position