4 INSTALLATION
0463 641 001
- 14 -
© ESAB AB 2018
4.3.1
Recommended fuse sizes and minimum cable area
WARNING!
An electrical shock or fire hazard is probable if the following electrical service guide
recommendations are not followed. These recommendations are for a dedicated
branch circuit sized for the rated output and duty cycle of the welding power source.
120 – 230 V, 1 ~ 50/60 Hz
Supply voltage
230 V AC
120 V AC
Input current at maximum output
32.1 A
30.0 A
Maximum recommended fuse* or circuit breaker rating
*Time delay fuse
33.0 A
30.0 A
Maximum recommended fuse or circuit breaker rating
50.0 A
50.0 A
Minimum recommended cord size
2.5 mm
2
(13 AWG)
2.5 mm
2
(13 AWG)
Maximum recommended extension cord length
15 m (50 ft)
15 m (50 ft)
Minimum recommended grounding conductor size
2.5 mm
2
(13 AWG)
2.5 mm
2
(13 AWG)
Supply from power generators
The power source can be supplied from different types of generators. However, some
generators may not provide sufficient power for the welding power source to operate
correctly. Generators with Automatic Voltage Regulation (AVR) or with equivalent or better
type of regulation, with rated power 8 kW, are recommended.