DESCRIPTION OF OPERATION
0740 800 186
- 28 -
© ESAB AB 2016
This supply is referred to as + 12 V CAN, its neutral point, 0 V CAN, is separated from the
electronic neutral (0 V).
The tolerance of the voltage is 11.5 to 14.5 V.
20AP1:2 The CAN bus
Bus communication circuits to and from the control board
A standardised communication (CAN - Controller Area Network) bus is used for
communication between the units of the equipment. Communication speed is 400 kbit/s.
The +12V CAN and 0V CAN power supply is unregulated and is galvanically isolated from
other parts of the control board.
The shell of the CAN-connectors and the shield of the CAN cables are connected to 0V CAN.
GND in the diagram is connected to the power source chassis.
Voltage regulator VR5 supplies a 5 V power supply to the CAN circuits on 20AP1.
Starting sequence
On power-up, the board's CAN controller reads in the bus speed from the micro processor:
400 kbit/s.
The circuit board displays the starting
sequence from power-up.
LED1 lights red. Then LED1, LED2 and LED3
lights green.
When the board has been initiated, and the
power source is in the application program,
LED1 flashes continously with a green light.
LEDs on circuit board 20AP1