bh20d12e

3

INTRODUCTION

The

Professional 250

are one transistor controlled welding power source designed

for welding with coated electrodes and for TIG welding (touch start).
The advanced electronics provide rapid control response, low power demand and

excellent welding characteristics. Inverter technology contributes to low weight and

compact dimensions of the units.

The rounded slimline shape of the unit makes it comfortable to carry. The strap can

be folded to serve as a carrying handle, or fully extended to serve as a shoulder

strap.

ESAB’s accessories for the product can be found on page

13

.

4

TECHNICAL DATA

Performance

:

at 35% duty cycle

at 60% duty cycle

at 100% duty cycle

250 A/30 V

180 A/27 V
140 A/26 V

Setting range

continuously variable 4--250 A

Open circuit voltage

50--80 V

Mains supply

:

voltage

frequency

fuse

mains cable, area

400 V AC

50/60 Hz

16 A*

4x1,5 mm

2

**

Enclosure class

IP 23

Application class
Dimensions L x W x H

472x142x256

Weight

11 kg

*When welding below 100 A a 10 A slow fuse is adequate..

**Power cable ratings complies with Swedish regulations..

Duty cycle

The duty cycle refers to the time as a percentage of a ten--minute period that you can weld at a cer-

tain load without overloading.

Application class

The symbol

indicates that the power source is designed for use in areas with increased

electrical hazard.

Enclosure class

The

IP

code indicates the enclosure class, i. e. the degree of protection against penetration by solid

objects or water. Equipment marked

IP23

is designed for indoor and outdoor use.

4.1

Equipment

Professional 250 is equipped with a remote control socket which activates

automatically when a remote control device is connected. NOTE! The contact pins L

and M must be strapped in the remote device’s connection cable for automatic

activation to function. The inverter is supplied with a 3 meter long mains cable.
Professional 250 is delivered with 5 meter long welding and return cables. These are

attached to cable connectors allowing quick change of polarity.

The manufacturer’s serial number is stamped on the rating plate.

GB

Содержание Caddy Professional 250

Страница 1: ...GB Valid for serial no 632 xxx xxxx 0457 552 301 GB 060814 Professional 250 Caddyt Instruction manual...

Страница 2: ...TION 5 4 TECHNICAL DATA 5 4 1 Equipment 5 4 2 Field of application 6 5 INSTALLATION 6 5 1 Placing 6 5 2 Connection 6 6 OPERATION 7 6 1 Overload protection 7 7 MAINTENANCE 7 7 1 Cleaning 7 8 FAULT TRAC...

Страница 3: ...l well acquainted with the operation of the welding equipment Incorrect operation of the equipment may lead to hazardous situations which can result in injury to the operator and damage to the equipme...

Страница 4: ...ARD S Sparks spatter can cause fire Make sure therefore that there are no inflammable materials nearby NOISE Excessive noise can damage hearing S Protect your ears Use earmuffs or other hearing protec...

Страница 5: ...472x142x256 Weight 11 kg When welding below 100 A a 10 A slow fuse is adequate Power cable ratings complies with Swedish regulations Duty cycle The duty cycle refers to the time as a percentage of a...

Страница 6: ...ere you gently stroke the tungsten electrode against the workpiece to establish the arc 5 INSTALLATION The installation must be executed by a professional WARNING This product is intended for industri...

Страница 7: ...ut that will trip before the temperature becomes too high You can tell when the rectifier has been overloaded because the yellow light comes on and it will no longer be possible to weld 7 MAINTENANCE...

Страница 8: ...S Check that the ratings of the welding power source have not been exceeded overload of the power source Poor welding result S Check that the welding and return cables are properly connected S Make s...

Страница 9: ...9 p...

Страница 10: ...Edition 060814 Diagram 10 bh20e11a...

Страница 11: ...Professional 250 Edition 060814 Ordering number 11 bh20o11a Ordering no Denomination Type 0457 516 880 Welding power source Professional 250 0457 552 990 Spare parts list Professional 250...

Страница 12: ...Professional 250 Edition 060814 Spare parts list 12 bh20s11a Item Qty Ordering no Denomination 1 1 0468 462 001 Filter 2 2 0467 796 001 Grille...

Страница 13: ...0349 501 024 Remote control unit AT1 MMA and TIG current 0459 491 896 Remote control unit AT1 CF MMA and TIG rough and fine setting of current 0459 491 897 Remote cable 12 pole 8 pole 5 m 10 m 15 m 2...

Страница 14: ...14 p...

Страница 15: ...15 p...

Страница 16: ...50 92 22 ESAB international AB Gothenburg Tel 46 31 50 90 00 Fax 46 31 50 93 60 SWITZERLAND ESAB AG Dietikon Tel 41 1 741 25 25 Fax 41 1 740 30 55 North and South America ARGENTINA CONARCO Buenos Aire...

Отзывы: