S0740 800 152/E061012/P36
-- 29 --
ci01i_ma6u6b
Synergy
Every combination of wire type, wire diameter and gas mixture requires a unique
relationship between wire feed speed and voltage (arc length) in order to ensure a stable
arc. The arc voltage (arc length) is automatically controlled in accordance with the
preprogrammed synergy line that has been selected by the welder, which makes it much
easier quickly to find the optimum welding parameters. The relationship between the wire
feed speed and the other parameters is referred to as the synergy characteristic or synergy
line.
Synergy ON:
the main menu shows the set wire feed, as well as
positive and negative deviation from the synergy line’s
voltage.
Positive deviation is displayed with a bar above SYN,
negative is displayed below.
Synergy OFF:
the main menu shows the set value for voltage and wire feed.
Activation of synergy performed in the main menu.
Synergy line package
The synergy line package supplied with the machine is called “
Standard
synergic lines” and
contains the 33 most frequently used synergy lines.
It is also possible to order other packages of synergy lines, but these must be installed by
an authorised ESAB service engineer.
Change of trigger data
Using this function, it is possible to switch to various pre--set welding data alternatives by
double--clicking on the welding gun’s trigger.
Switching takes place between the memory positions 1, 2 and 3 (see under chapter
“memory management”). If there is no data in memory position 2, switching takes place
instead between positions 1 and 3.
ON -- Switching between memory positions can take place before, after or during welding.
ARC OFF -- Switching between memory positions can only take place before or after
welding.
-- Activation of trigger data switching performed in the configuration menu.
AVC feeder
When this function is activated it is possible to use an Arc Voltage Controlled or
Off--The--Arc feeder, where the arc voltage from the power source is used to power the feed
unit.