7.3
Settings in the weld data setting menu
Settings for dip--/spray arc alternative pulsing see chapter
3.1.1
and
3.1.2
.
Settings
Setting range
In steps of:
Values after
reset
Synergic
depend-
ent
Adjust--
able in
synergic
Phase
Primary or
secondary
--
Primary
x
Phase weld time
0 -- 2.50 s
0,01
0.05 (secondary)
0.22 (primary)
x
7.4
Function explanations for settings
The function explanations for settings for Superpulse and other MIG/MAG--welding
see pages
17--20
.
7.4.1
Phase
In this function you can choose between primary or secondary.
High data is set in primary and low data is set in secondary.
The settings are used to determine whether primary or secondary data should be
available for editing. It also determines which data is affected in measuring and
remote modes. The wire feed speed shown in the measure image shows the speed
in the selected phase. However, the voltage, current and weld output are based on
the measurement under both phases.
You can choose different synergy in the primary and secondary phases. Note that
you must make the same selection in both primary and secondary when the same
synergy is required.
-- Phase is set in the
main menu.
7.5
Wire feed unit
Use only wire feed unit Feed 3004, Aristo
t
with MIG SUPERPULSE.
Precautions!
When using MIG SUPERPULSE there is a high load on the wire feed unit. To ensure
that the reliability of the feed unit is not endangered follow the limits in the diagram
below.