ESA Tribo-Check TC30 Скачать руководство пользователя страница 6

DICHIARAZIONE DI CONFORMITA' DEL COSTRUTTORE

CONFORMITY DECLARATION OF THE MANUFACTORY

Mesero, 14 marzo, 2006

G. BELLINELLI

Amministratore delegato / Managing director

ESA ELECTRONIC ENGINEERING s.r.l.

Nome del costruttore:

ESA Electronic Engineering

Indirizzo del costruttore:

via J.Kennedy 28 I 20010 Mesero (Mi) Italia

Dichiara che il prodotto:

Nome del Prodotto(i): 

Controllo Emissioni

Modello:

TC30-

Opzioni del prodotto:

Tutte

E' conforme alle seguenti direttive:

Direttiva Macchine 2006/42/CE 'compatibilità
elettromagnetica' 
rispondenti alle
norme Europee armonizzate
EN61000-6-2:2005 classe B della norma 
EN61000-6-4:2001

Direttiva Bassa Tensione (DBT) 2006/95/CE
rispondente alle norme Europee armonizzate
EN 60947-1:2004

Informazioni supplementari:

I prodotti sono stati sottoposti a test in
configurazione tipica e con potenza di carico
2 watt

Manufactory name:

ESA Electronic Engineering

Manufactory address

via J.Kennedy 28 I 20010 Mesero (Mi) Italia

Declare that the device:

Device(s) name: 

Emission Control

Model:

TC30-

Device options:

All

Meets the following directive:

Machine Directive 2006/42/CE 
'electromagnetic compatibility'
related to the
European Standard
EN61000-6-2:2005 class B of the rule 
EN61000-6-4:2001

Low Voltage Directive 2006/95/CE related to the
European Standard EN 60947-1:2004

Additional informations

the devices were tested in typical configuration
with load power of 2 watt

Содержание Tribo-Check TC30

Страница 1: ...s operation principle is founded on the TRIBO ELECTRIC T E effect This physical phenomenon is caused by the friction of particles suspended in the air against the surface of a probe which is placed in the measurement area Particular electronic circuits which are located inside the probe allow to transform the static electricity generated by the T E phenomenon into the electric signal proportional ...

Страница 2: ...the direct exposure to sun light 2 6 Every kind of operation on TC probe must be done without dust in the air and when it is possible with supply voltage Off 2 7 A remarkable quantity of rain or water in the sampled gases could distort the reading of the signal 3 WIRING DIAGRAM 4 TECHNICAL FEATURES Supply Voltage 16 24 VDC 100 mA Output signal 4 20 mA Activ Maximum load 350 Ohm GAS temperature 120...

Страница 3: ...to allow the introduction of dust This hole should be positioned in vertical line duct under the TC probe at a certain distance to assure isokinetic conditions in the point of measurement see next picture A 5 3 FASTENING The standard BS40 flange is a muff male thread of 1 GAS with 35 mm hole BS40 is fixed to the duct by means of a welding on the same axis where the 35mm hole has been made See the ...

Страница 4: ...ns the value must be 4mA value pre determined by the calibration from the manufacturer s laboratory 2 With the maximum value of emissions estimated the signal must be around 14 18 mA In practice if according to law regulations for certain types of material the maximum level of emissions allowed is equal to 20 mg m3 the STC signal must be adapted to this value in the presence of maximum emissions Y...

Страница 5: ...ling duct in a pre fixed time and measure the STC signal generated by the TC probe For this calibration it is necessary to know the range of the duct The calibration for simulation cannot be done in the absence of dust The following example indicates how to proceed Range of the duct 100000 m3 h Emission that you wish to simulate 10 mg m3 Time of insertion of dust in the duct 60sec Quantity of dust...

Страница 6: ...rma EN61000 6 4 2001 Direttiva Bassa Tensione DBT 2006 95 CE rispondente alle norme Europee armonizzate EN 60947 1 2004 Informazioni supplementari I prodotti sono stati sottoposti a test in configurazione tipica e con potenza di carico 2 watt Manufactory name ESA Electronic Engineering Manufactory address via J Kennedy 28 I 20010 Mesero Mi Italia Declare that the device Device s name Emission Cont...