1.1 DESCRIPTION

Master unit for BUS SYSTEM for dedusting plant cleaning cycle control with digital dP control by internal transducer.

2.1 STANDARD FEATURES

A1a

Minimum and maximum dP alarms on same relay (K2)

A2a

Relay Voltage ON (K1)

B10a

Manual activation of every single output from keyboard

B1a

Select Number of outputs

B2x

Activation time from 0.05 to 5.00 sec.

B3c

Interval time between ev. during post-cleaning

B3x

Interval time from 1 to 999 sec.

B8b

Short-circuit protection of every single output

B9b

Electric control of output activation

C1

Digital differential pressure control (STOP at cycle end)

C13_10

dP full range 10.00 kPa = 100.0 mbar = 1012 mmH2O.

C4

Cleaning cycle

C4a

Automatic operation mode

C4b

Manual operation mode

C7c1

Minimum dP alarm. Contact open with alarm. Automatic reset.

C7d1

Maximum dP alarm. Contact open with alarm. Automatic reset.

C8

dP zero readout regulation

D14a

Operation hours-counter

D1b1

Additional post-cleaning cycles from dP readout. Activation at STOP.

D5a

Consent from external compressed air pressure switch

D6a

ON/OFF cleaning cycle from external contact

G1

Maximum load power 25W per output

SL

Multi language display

Code:

DSA

GENERIC DOCUMENTATION. THE SPECIFIC DOCUMENTATION IS ATTACHED TO THE SEQUENCER

Содержание DSA

Страница 1: ...ut from keyboard B1a Select Number of outputs B2x Activation time from 0 05 to 5 00 sec B3c Interval time between ev during post cleaning B3x Interval time from 1 to 999 sec B8b Short circuit protection of every single output B9b Electric control of output activation C1 Digital differential pressure control STOP at cycle end C13_10 dP full range 10 00 kPa 100 0 mbar 1012 mmH2O C4 Cleaning cycle C4...

Страница 2: ...1 sec the minimum settable interval time is Minumum interval time 5 times pulse time B2x B8b Short circuit protection of every single output In case of short circuit the corresponding output is automatically skipped Relay K2 will signal the alarm condition and display will show the alarm situation code E1 See the alarm description Press key E to reset the alarm B9b Electric control of output activ...

Страница 3: ...fter the fan stop Their number can be set from 0 to 99 by keyboard The sequencer will automatically recognise the fan state by comparing the dP readout with the threshold in set code 11 dP set 11 fan on dP set 11 fan off Post cleaning cycles are activated even if dP 0 When the fan is off or dP set 11 the display shows FAN STOP The display shows POST CLEANING ACT during additional cycles and if the...

Страница 4: ... written to the database even if outside the established time interval D11 Emission control by TRIBO CHECK probe Alarms on relay K2 By connecting the Tribo Check probe to the device it is possible to keep under control the dust emission in the duct The TC probe management contain some function and possible alarm situations that allow to find if there is a broken bag or a continuos emission over a ...

Страница 5: ... threshold set up in Setup for 3 consecutive cycles this will trigger the E3 alarm for broken bag see alarm description and the solenoid valve that has caused the emission will be excluded from the cleaning cycle One single solenoid valve at a time can be excluded from the cleaning cycle In the example shown by the graph the sensitivity is set to 5 and activation of the electrovalves 3 for 3 conse...

Страница 6: ...essed in mg m3 The display will show the numeric value corresponding to a 20 mA signal from the TC probe 20 default value For this regulation you shall enter a well known dust quantity in the duct e g 10 mg m3 and check the readout of the operating equipment on the display e g 15 Press key B and D in set up function 22 at the same time The display will show L TC READOUT and 001 mg m3 Press key A a...

Страница 7: ...y using wet cloth 3 9 For supply voltages cabling and voltages applicable to the relay contacts follow the current rules 3 10 For all input control signals to the Timer D1a D5 D6 use anti flame wires with a minimum section of 0 5 mm 3 11 For the electrical connection of the supply voltage and BUS line use anti flame wires with a minimum section of 0 75 mm For output relay contacts use anti flame w...

Страница 8: ...001 999 B3c 5 sec 06 POST CYCLES D1x 002 cycles Number additional cycles after fan stop 00 99 D1x 5 07 ELECTROVAL N B1b 016 ev Selection Number of electrovalves B1b 08 EV TEST B10 001 OFF TEST Manual activation of every single ev from keyboard B10 09 HOURS COUNTER D14a 00000 Hours Operation hours counter 0 65535 D14a 10 ZERO dP ADJ C8 0 00 kPa dP zero readout regulation C8 0 00 11 FAN THRESHOLD D1...

Страница 9: ...X dP ALARM C7d1 3 00 kPa Maximum dP alarm threshold 0 01 9 99 C7d1 3 00 90 GSM CONTROL S01 OFF GSM control and SMS sending Inclusion Exclusion GSM1 92 MOBILE NUMB 39123456789 Mobile number to send SMS in case of alarm Key C select digit Key A change value of selected digit GSM1 ...

Страница 10: ...HRES D12c 050 mg m3 Continuous emission alarm threshold 1 99 D12b1 24 SENSITIVITY D21 5 06 mA Sensitivity for broken bag check 0 9 D21 26 TC MEAN TIME D19 010 sec TC probe signal readout average time 1 60 D19 27 mA TC READING D20 04 0 mA TC output current in mA D20 L TC READING 001 mg m3 TC reading on display during test for mg m3 adjustment Press D and B See D18 1 99 D18 A REAL EMISSION 001 mg m3...

Страница 11: ... level GSM version only Keyborad locked Contact the supplier of the filter 7 1 DISPLAY INDICATIONS WITH ALARM DISPLAY DESCRIPTION Code E1 OVERLOAD ELECTROVALVE 003 Overload alarm solenoid valves 3 B8b E2 ACT FAILED ELECTROVALVE 003 Solenoid valve not activated Solenoid valves 03 option on request B9x B6x ...

Страница 12: ...ove the set threshold D12c E5 PROBE SIGNAL D12c TRIBO 2mA TRIBO CHECK probe signal below 2 mA D12c E6 COMPR AIR LACK D5a OPEN Cycle stop since no consent from compressed air pressure switch D5a E7 MAXIMUM dP ALARM Maximum dP alarm active dP reading over SET 15 See section 5 1 C7d E8 MINIMUM dP ALARM Minimum dP alarm active dP reading under SET 12 See section 5 1 C7c 8 1 INFORMATION AND GUIDE ON TH...

Страница 13: ...9 1 WIRING DIAGRAM ...

Страница 14: ...10 1 ELECTRONIC BOARD SIZE AND VOLTAGE SETTINGS ...

Страница 15: ...11 1 ENCLOSURE DIMENSIONS ...

Страница 16: ...le do not run in according to the set value The memory of the microprocessor could be modified by external factor Switch Off the supply voltage of the sequencer Hold down key B and switch on the supply voltage By means of this operation the default data are loaded in set up Adjust the zero dP reading and the other parameters according to the filter s needs 13 1 WARRANTY The warranty lasts 4 years ...

Страница 17: ...ation DSA The object of the declaration described above is in conformity with the relevant Union harmonisation legislation The object of the declaration described above is in conformity with the relevant Union harmonisation legislation Directives 2014 30 UE 2014 35 UE and 2011 65 UE Directives 2014 30 UE 2014 35 UE and 2011 65 UE The following harmonised standards and technical specifications have...