9….. Dispensing Indicator 

The indicator will light up during dispensing. 

 

Table 2

Timer setting 

PCB main board 

Timer Knob 0 

Timer Knob 10 

Setting 

1on 

0.1 sec 

1.3 sec 

Default 

2on 

1 sec 

13 sec 

 

3on 

10 sec 

36 sec 

 

4on 

30 sec 

50 sec 

 

1 and 2 on 

50 sec 

70 sec 

 

3 and 4 on 

70 sec 

90 sec 

 

All on 

90 sec 

110 sec 

 

 

4. Operation

 

a. 

Please refer to table 1 for appropriate needle and pressure setting. 

b. 

If the adhesive is dripping from barrel, turn up the vacuum until it is not dripping. 

c. 

Turn off the timer switch; use the foot pedal to activate the dispensing until the adhesive fill up the needle and 

flow out the barrel smoothly. If the adhesive cannot flow out the barrel please adjust the pressure or replace the 

needle and repeat step a again. 

d. 

Place the barrel 45 degree to the process object and fit the needle on top of the dispensing point. 

e. 

– Manual dispensing

turn off the timer switch and step on the foot pedal to activate the dispensing, remove to 

stop the dispensing. It is suitable for long straight line and irregular dispensing route. 

– Timer dispensing

turn on the timer switch and set the timer; step on the foot pedal once to activate one single 

timed dispensing, repeat the process by stepping the pedal again. It is suitable for repeat and uniform dispensing 

route. 

 

5.  Three main reasons that control the dispensing volume

 

 

Needle type and size 

 

Air pressure volume   

      Dispensing time 

 

6.  Maintenance and Precaution

 

The dispenser is designed and built to be relatively maintenance free. To assure trouble free operation, the following 

Содержание ES2060

Страница 1: ...ressor line b Connect the Foot Pedal on the back of the system or Finger Switch on the front of the system c Fill the dispensing barrel with adhesive up to 2 3 full and adapt with barrel adapter Connect the adapter to the front of the system d If you are using Finger Switch please stick the switch on the dispensing barrel e Connect the Power Cord on the back of the system and switch the power on P...

Страница 2: ...se dispensing you will need to use low pressure dispenser 0 30 psi 3 Control Setting 1 Pressure Indicator Display the currently air pressure in the system 2 Pressure Regulator Adjust the air pressure in the system increase with clockwise and decrease with counter clockwise 3 Barrel Adapter Port Connect with barrel adapter press down and rotate to adapt 4 Vacuum Knob Adjust the suck back pressure i...

Страница 3: ...ly If the adhesive cannot flow out the barrel please adjust the pressure or replace the needle and repeat step a again d Place the barrel 45 degree to the process object and fit the needle on top of the dispensing point e Manual dispensing turn off the timer switch and step on the foot pedal to activate the dispensing remove to stop the dispensing It is suitable for long straight line and irregula...

Страница 4: ...tional or place the barrel on the barrel stand to prevent solidification 7 Troubleshooting Problem Possible Cause Correction Indicator or display does not light no power input PCB main board damage check power cord connection turn on power replace new PCB main board Cannot dispense foot pedal not plugged in properly defective foot pedal foot pedal port broken or loosen defective Solenoid Valve che...

Страница 5: ...ive product or subassembly and components under warranty will be repaired or replaced at Ever Sharp option free of charge Customer with defective product under warranty must contact the nearest Ever Sharp office or distributor to secure a return authorization prior to shipping the product to the assigned Ever Sharp authorized service center For nearest Ever Sharp office or distributor contact info...

Отзывы: