9….. Dispensing Indicator
The indicator will light up during dispensing.
Table 2
:
Timer setting
PCB main board
Timer Knob 0
Timer Knob 10
Setting
1on
0.1 sec
1.3 sec
Default
2on
1 sec
13 sec
3on
10 sec
36 sec
4on
30 sec
50 sec
1 and 2 on
50 sec
70 sec
3 and 4 on
70 sec
90 sec
All on
90 sec
110 sec
4. Operation
:
a.
Please refer to table 1 for appropriate needle and pressure setting.
b.
If the adhesive is dripping from barrel, turn up the vacuum until it is not dripping.
c.
Turn off the timer switch; use the foot pedal to activate the dispensing until the adhesive fill up the needle and
flow out the barrel smoothly. If the adhesive cannot flow out the barrel please adjust the pressure or replace the
needle and repeat step a again.
d.
Place the barrel 45 degree to the process object and fit the needle on top of the dispensing point.
e.
– Manual dispensing
:
turn off the timer switch and step on the foot pedal to activate the dispensing, remove to
stop the dispensing. It is suitable for long straight line and irregular dispensing route.
– Timer dispensing
:
turn on the timer switch and set the timer; step on the foot pedal once to activate one single
timed dispensing, repeat the process by stepping the pedal again. It is suitable for repeat and uniform dispensing
route.
5. Three main reasons that control the dispensing volume
:
Needle type and size
Air pressure volume
Dispensing time
6. Maintenance and Precaution
:
The dispenser is designed and built to be relatively maintenance free. To assure trouble free operation, the following