16
Complete programming table (and II)
D1 D2 Parameter
D3
D4
Pre-set
option
Options or values
A
0
Flashing light
0
1
,
2
01
01
: without pre-warning
02
: with pre-warning
1
Garage light time
0
...
5
.
0
...
9
03
03
= 3 sec.;
59
= 59 sec.;
2
.
5
= 2 min. 50 sec.;
....; maximum 4 minutes
2
Gate speed
T h e o p e n / c l o s e r u n m u s t b e
r e p r o g r a m m e d w h e n e v e r t h i s
parameter is changed
0
1
...
9
03
01
: minimum speed (40Hz);
02
: 45Hz,
03
: 50Hz,
04
: 55Hz, ...;
09
: maximum speed (80Hz)
3
Slowdown speed
T h e o p e n / c l o s e r u n m u s t b e
r e p r o g r a m m e d w h e n e v e r t h i s
parameter is changed
0
1
...
9
03
01
: minimum speed (21Hz);
02
: 22Hz,
03
: 23Hz,
04
: 24Hz, ...;
09
: maximum speed (29Hz)
5
Reverse after closing (prevents the
operator from seizing up on the
stopper)
0
0
...
5
00
00
: no reverse;
...;
05
: maximum reverse
6
Maximum entrapment current
(each value equivalent to 0.5A).
T h i s o n l y w o r k s i n
electromechanical operators.
Digit D3 can be used to set the
current of operator 1;
Digit D4 can be used to set the
current of operator 2
0
...
9
0
...
9
00
00
: disabled;
01
: disabled in operator 1 and 0.5A in operator 2;
10
: 0.5A in operator 1 and disabled in operator 2;
….;
65
: 3A in operator 1 and 2.5 in operator 2;
…;
99
: 4.5A in operator 1 and in operator 2
7
Crossing over photocell (opening
or closing) during stand-by (in
automatic mode only)
0
0
...
2
02
00
: does not affect stand-by time
01
: immediate close when the photocells are released
02
: restarts standby time
8
Effect of ST1-ST2 pushbuttons
during stand-by time (in automatic
mode only)
0
0
...
2
02
00
: have no effect during stand-by
01
: produce immediate closing
02
: restart stand-by time
9
Opening mode
0
1
...
3
02
01
: collective opening
02
: step-by-step alternative stop
03
: automatic alternative stop (if
F200
is selected,
A903
becomes
A902
)
A
Lapse between leaves in opening
and closing
0
...
9
0
...
9
22
00
: no lapse in opening or closing (apply only in gates
with no overlap);
XY
:
X
lapse in opening
(
X
=
1
: 1 second, ... ,
X
=
9
: 9 seconds)
Y
lapse in closing
(
Y
=
1
: 1 second, ... ,
Y
=
9
: 9 seconds)
b
Using the EPS1 card connector
For parameters
Ab02
and
Ab03
,
use the EPS1 card and bridge the
network input cable connectors
instead of connecting them to the
network (see “Brake connection”
diagram)
0
0
...
3
00
00
: use for standard traffic light;
01
: use for brakes
02
: NC contact with gate open (L1-COM) and gate
closed (L2-COM)
03
: impulse 1 second Open (L1-COM) when starting
opening and Close (L2-COM) when starting
closing. Allows another panel to be enabled
C
Hydraulic pressure maintenance
0
0
...
6
00
00
: no pressure maintenance;
01
: every 0.5 hours;
02
: every 1 hour;
03
: every 2 hours;
04
: every 6 hours;
05
: every 12 hours;
06
: every 24 hours
d
Hammer
0
0
,
1
00
00
: no hammer;
01
: with hammer
E
Special functions
0
0
...
2
00
00
: no special function;
01
: opening photocell
C4
programmed for pedestrian
crossing;
02
: industrial;
N
0
Programming lock key
Be sure to remember any key used,
f o r f u t u r e a c c e s s t o t h e
programming
0
0
,
1
0000
The preset option is
0000
(no key). If any figure is
changed, this is considered key.
Select the required key (starting with D1) using UP
and DOWN. Press ESC to cancel or ENTER to confirm
and move to D2, and so on.
1
Total operations completed
X
X
Indicates the hundreds of cycles completed (for
example,
68
indicates 6800 cycles completed)
2
Partial operations completed
X
X
Indicates the hundreds of cycles completed. It can be
reset by pressing ST1, ST2 and ENTER simultaneously.
t
0
FTP communication
O
ç
Immediate communication with the server
1
GSM signal strength
X
X
Indicates signal strength