Complete programming table (and II)

D1 D2 Parameter

D3

D4

Pre-set 
option

Options or values

A

0

Flashing light

0

1

2

01

01

: without pre-warning

02

: with pre-warning 

1

Garage light time

0

...

5

.

0

...

9

03

03 

= 3 sec.;

 59 

= 59 sec.; 

2

.

5

 = 2 min. 50 sec.;

....; maximum 4 minutes

2

Gate speed
T h e   o p e n / c l o s e   r u n   m u s t   b e
r e p r o g r a m m e d   w h e n e v e r   t h i s
parameter is changed

0

1

...

9

03

01

: minimum speed (40Hz);

02

: 45Hz, 

03

: 50Hz, 

04

: 55Hz, ...;

09

: maximum speed (80Hz)

3

Slowdown speed
T h e   o p e n / c l o s e   r u n   m u s t   b e
r e p r o g r a m m e d   w h e n e v e r   t h i s
parameter is changed

0

1

...

9

03

01

: minimum speed (21Hz);

02

: 22Hz, 

03

: 23Hz, 

04

: 24Hz, ...;

09

: maximum speed (29Hz)

5

Reverse after closing (prevents the
operator from seizing up on the
stopper)

0

0

...

5

00

00

: no reverse;

...;

05

: maximum reverse

6

Maximum entrapment current
(each value equivalent to 0.5A).

T h i s   o n l y   w o r k s   i n
electromechanical operators.
Digit D3 can be used to set the
current of operator 1;
Digit D4 can be used to set the
current of operator 2

0

...

9

0

...

9

00

00

: disabled;

01

: disabled in operator 1 and 0.5A in operator 2;

10

: 0.5A in operator 1 and disabled in operator 2;

….;

65

: 3A in operator 1 and 2.5 in operator 2;

…;

99

: 4.5A in operator 1 and in operator 2

7

Crossing over photocell (opening

or closing) during stand-by (in
automatic mode only)

0

0

...

2

02

00

: does not affect stand-by time

01

: immediate close when the photocells are released

02

: restarts standby time

8

Effect of ST1-ST2 pushbuttons
during stand-by time (in automatic
mode only)

0

0

...

2

02

00

: have no effect during stand-by

01

: produce immediate closing

02

: restart stand-by time

9

Opening mode

0

1

...

3

02

01

: collective opening

02

: step-by-step alternative stop

03

: automatic alternative stop (if 

F200

 is selected,

A903

 becomes 

A902

)

A

Lapse between leaves in opening
and closing

0

...

9

0

...

9

22

00

: no lapse in opening or closing (apply only in gates

with no overlap); 

XY

:

X

 lapse in opening 

(

X

=

1

: 1 second, ... , 

X

=

9

: 9 seconds)

Y

 lapse in closing

(

Y

=

1

: 1 second, ... , 

Y

=

9

: 9 seconds)

b

Using the EPS1 card connector
For parameters 

Ab02

 and 

Ab03

,

use the EPS1 card and bridge the
network input cable connectors
instead of connecting them to the

network (see “Brake connection”
diagram)

0

0

...

3

00

00

: use for standard traffic light;

01

: use for brakes

02

: NC contact with gate open (L1-COM) and gate

closed (L2-COM)

03

: impulse 1 second Open (L1-COM) when starting

opening and Close (L2-COM) when starting
closing. Allows another panel to be enabled

C

Hydraulic pressure maintenance

0

0

...

6

00

00

: no pressure maintenance; 

01

: every 0.5 hours;   

02

: every 1 hour;  

03

: every 2 hours;   

04

: every 6 hours;  

05

: every 12 hours;   

06

: every 24 hours 

d

Hammer

0

0

,

1

00

00

: no hammer;  

01

: with hammer

E

Special functions

0

0

...

2

00

00

: no special function; 

01

: opening photocell 

C4

 programmed for pedestrian

crossing; 

02

: industrial;

N

0

Programming lock key
Be sure to remember any key used,
f o r   f u t u r e   a c c e s s   t o   t h e
programming

0

0

,

1

0000

The preset option is 

0000

 (no key). If any figure is

changed, this is considered key. 
Select the required key (starting with D1) using UP
and DOWN. Press ESC to cancel or ENTER to confirm
and move to D2, and so on.

1

Total operations completed

X

X

Indicates the hundreds of cycles completed (for
example, 

68

 indicates 6800 cycles completed)

2

Partial operations completed

X

X

Indicates the hundreds of cycles completed. It can be
reset by pressing ST1, ST2 and ENTER simultaneously.

t

0

FTP communication

O

ç

Immediate communication with the server

1

GSM signal strength

X

X

Indicates signal strength

Содержание VIVO-I103

Страница 1: ...s or functions may differ or be unavailable if your firmware is older than shown in this guide Electrical wiring A Main power supply B F Flashing light with antenna C Photocells Rx Tx D Key switch E O...

Страница 2: ...n GND common COM GND screen GND common COM SGN1 green or blue wire SGN1 opening FCA SGN1 green or blue wire SGN1 VUS operator safety micro SGN2 do not connect SGN2 closing FCC SGN2 white wire SGN2 ele...

Страница 3: ...2 closing FCC SGN2 purple wire SGN2 do not connect SGN2 closing FCC G1 open G2 close G3 common In sliding gates C302 and up and over doors C303 it is only possible to use a single motor M1 which shoul...

Страница 4: ...n Display indications In swing gates C4 refers to the interior photocell and C5 to the exterior photocell instead of opening and closing respectively D3 and D4 during operation 88 8 FT1 enabled 888 FT...

Страница 5: ...ck of A2 operator turning direction C2 R294I 9 1 Press ENTER with the display showing CL88 or rSXX rS 8 rS 8 rS8 rS8 etc P294B 2 R294F 6 R294G 7 R294H 8 This procedure is the same as for operator A1 b...

Страница 6: ...nd closing stopper must be installed before programming the travel see the operator manual 15 Start slowdown of leaf 2 with ST1 only with CA01 or CA03 I II U294R 16 Finish closing of leaf 2 with ST1 I...

Страница 7: ...stalled 01 with single encoder 02 with limit switches 03 with dual encoder 04 with encoder and limit switches not available with C301 selected 05 VULCAN VUS and ATLAS ATS G6xxI only available with C30...

Страница 8: ...op 03 automatic alternative stop if F200 is selected A903 becomes A902 A Lapse between leaves in opening and closing 0 9 0 9 22 00 no lapse in opening or closing apply only in gates with no overlap XY...

Отзывы: