![Erreka RINO-I Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/erreka/rino-i/rino-i_quick-installation-and-programming-manual_2424325009.webp)
9
D1
D2
Parameter
D3
D4
Pre-set option Options or values
C
1
Motor turning direction
0
1
x
0
2
3
Type of gate
0
2
x
Sliding gate
0
3
Up&over door, with shadow function
4
Opening safety device (photocell or
strip)
0
0
x
Device not installed
1
0
Device without testing
1
1
Device with testing
5
Closing safety device (photocell or
strip)
Closing photocell with
C520
or
C521
,
also prevents the start of gate opening
0
0
x
Device not installed
1
0
Device without testing
1
1
Device with testing
2
0
Device without testing
2
1
Device with testing
7
Encoder and limit switches
(when using external limit switches,
connect them to the corresponding
terminals of the control board)
0
0
No encoder or limit switches
0
2
With internal limit switches
0
4
x
With encoder and internal limit switches
0
6
With external limit switches
0
7
With encoder and external limit switches
8
Radio receiver
0
1
RSD card (frame, not decoder)
0
2
x
Twin-channel decoder card
9
Safety strip type
0
1
x
Contact edge
0
2
Resistive edge
A
Slowdown
0
0
No slowdown
0
1
x
Slowdown in opening and closing
0
2
Slowdown in opening
0
3
Slowdown in closing
P
1
T o t a l o p e n i n g r a d i o c o d e
programming
o
ç
2
P e d e s t r i a n o p e n i n g r a d i o c o d e
programming
o
ç
3
Gate travel programming
o
ç
F
1
Key command using ST1 and ST2
pushbuttons
0
0
ST1 and ST2 without effect, key commands
are made by radio (channel 1: total
opening-closing, channel 2: pedestrian
opening-closing)
0
1
x
ST1 total opening-closing, ST2 pedestrian
opening-closing
0
2
ST1 total opening, ST2 total closing
0
3
Dead-man mode
0
4
Dead-man mode in closing
2
Operation mode (semi-automatic or
automatic) and stand-by time (in
seconds) in automatic mode
0
...
5ÿ
0
...
9
00
00
: semi-automatic mode
01
: automatic mode and stand-by time 1
second; ...
59
: automatic mode and stand-by time 59
sec.;
1ÿ0
: 1 min. 0 secs.; ....; maximum 4 minutes
3
Pedestrian opening
0
...
9
0
...
9
40
00
: Pedestrian opening is not carried out
01
: 1% of total opening
12
: 12% of total opening
99
: 99% of total opening (equivalent to
100%)
4
Pedestrian closing operation mode
(semi-automatic or automatic) and
stand-by time (in seconds) in automatic
mode
0
...
5ÿ
0
...
9
00
00
: semi-automatic mode
01
: automatic mode and stand-by time 1
second; ...
59
: automatic mode and stand-by time 59
sec.;
1ÿ0
: 1 min. 0 secs.; ....; maximum 4 minutes
Complete programming chart