Erreka PR110 Скачать руководство пользователя страница 1

INSTRUCTION MANUAL

 

PR110, PR112, PR114, PR116

PR110 

PR112 

PR114 

PR116

Learning rolling code

:

 

1. Press learning key of receiver the LED will flash indicating the status of learning.

2. Press any button of the keyfob or press pushpad.

3. Press Learn on receiver to confirm as the pilot lamp flash 5 time slowly.  

4. Press same button of the keyfob or press pushpad to confirm learn.

Delete memory message

 

Press  the learning key  of  the receiver for 8 seconds until the LED stops, which indict  
success to delete the memory message. 

DATA

Working voltage

DC12V/ 24V (optional)

Static working current

7mA

Working temperature

-40

  

to 

+80

Receiving sensitive

-105dBm

Working frequency

315MHz

433MHz (optional)

Contact current

10A