![Erreka PR110 Скачать руководство пользователя страница 1](http://html1.mh-extra.com/html/erreka/pr110/pr110_instruction-manual_2424404001.webp)
INSTRUCTION MANUAL
PR110, PR112, PR114, PR116
PR110
PR112
PR114
PR116
Learning rolling code
:
1. Press learning key of receiver the LED will flash indicating the status of learning.
2. Press any button of the keyfob or press pushpad.
3. Press Learn on receiver to confirm as the pilot lamp flash 5 time slowly.
4. Press same button of the keyfob or press pushpad to confirm learn.
Delete memory message
Press the learning key of the receiver for 8 seconds until the LED stops, which indict
success to delete the memory message.
DATA
Working voltage
DC12V/ 24V (optional)
Static working current
≤
7mA
Working temperature
-40
℃
to
+80
℃
Receiving sensitive
≥
-105dBm
Working frequency
315MHz
、
433MHz (optional)
Contact current
≤
10A