Erreka CLEVER03 Скачать руководство пользователя страница 3

7

Photocell shade function in up-and-over door (DIP9=OFF)

: when the photocell shadow function is enabled, the photo-

cell is invalidated in the last part of the closing run. To do this, the control panel detects the position in which the leaf enables
the photocell while programming the closing run, and takes it as a reference for invalidation during operations (invalidation
comes about a moment before the point detected during programming).

Total opening radio code programming

Ensure JP1 is configured correctly 
before starting:
– JP1=ON (bridge): Roller Code
– JP1=OFF (open): Fixed Code

                                                                         

 1 

Place DIP1 in ON and close the leaf,
holding down ST2.

                                                                          

 2 

When using fixed code transmitters,
select the code in the transmitter.

 3 

Place the DIPs as shown in the figure
(DIP1=ON, DIP4=ON). DL3 and DL2
light up to show programming mode
enabled.

                                                                         

 4 

Press the button for the required
channel. DL2 flashes twice when
programming is complete. 

DL2 flashes 6 times if the memory is
full.

 5 

Place DIP1 and DIP4 in OFF.
DL3 and DL2 remain off. 

                                                                          

 6 

Disconnect and reconnect the
electrical power supply.

                                                                    

Programming Roller transmitters via
programmed Roller transmitter

: with

the door closed, bridge between cable
connectors 1 and 5 of the programmed
transmitter: DL3 and DL2 light up for 10
s e c o n d s .   P r e s s   t h e   b u t t o n   f o r   t h e
transmitter to be programmed: DL2
flashes twice and the programming
process ends.

                                                                    

Programming is carried out in the same
way, using DIP6 instead of DIP4.

With Roller transmitters, the button which
will enable pedestrian opening is stored.
This button is assigned to all transmitters
stored for total opening.

R311A

ST2

R311C

R311B

I

II

R311L

R311K

Pedestrian opening code

Deleting total opening radio code

 1 

Place DIP1 in ON and DIP4
in ON.

 2 

Keep ST1 and ST2 held
down at the same time for
5 seconds, until DL1, DL2
and DL3 flash quickly.

 3 

Release ST1 and ST2. 

 4 

Hold ST1 down for 5
seconds to confirm.

B311A

B

ST1  + ST2

5s

B311C

ST1  

ST2

B311D

ST1

5s

It can be deleted in the same way by using DIP6 instead of DIP4, and
ST2 instead of ST1 in the final step.

Pedestrian opening radio code

(all the stored codes are deleted, independently of
JP1 being selected)

Total open/close programming

 1 

Select the type of door using DIP9
(sliding or up-and-over).

                                                                           

 2 

Place DIP1 in ON and close the leaf,
holding down ST2.

                                                                           

 3 

Place DIP1 in ON, DIP2 in ON, DIP5 in
OFF, DIP8 in ON (if using slowdown). 

DL3 lights up (programming enabled).

                                                                           

 4 

Press ST1 to start opening the leaf.  

 5 

Press ST1 to start slowdown (with
DIP8=ON only).

                                                                           

 6 

Press ST1 to finish opening (pressing
ST1 is not necessary if FCA is installed).  

                                                                           

 7 

Press ST1 to start closing the leaf.

 8 

Press ST1 to start slowdown (with
DIP8=ON only).

                                                                           

 9 

Press ST1 to finish closing (pressing ST1
is not necessary if FCC is installed).   

                                                                           

 10 

Place DIP1 and DIP2 in OFF. DL3

remains off.

R311A

ST2

G311B

G311C

G311D

G311E

G311F

G311G

G311J

G311K

Отзывы: