Erreka CLEVER03 Скачать руководство пользователя страница 1

5

CLEVER03

Quick installation and programming guide

English

IMPORTANT 

NOTE

This quick guide is a summary of the complete installation guide. The guide contains safety warnings and other
explanations that must be taken into account. The most recent versions of this guide and the installation
manual are available in the "Downloads" section on Erreka's website. 

http://www.erreka-automation.com

The options and functions described in this guide apply for the firmware version indicated on the circuit. The
firmware, as part of a process of continuous improvement, is subject to new functionalities or upgrades being
included as a result of new versions which are not necessarily compatible with previous ones. For this reason,
some options or functions may differ or be unavailable if your firmware is older than shown in this guide.

E311A

ELECTRICAL WIRING:

Element

Nº wires per section

Maximum length

A: Main power supply

3x1.5mm

2

30m

B: Garage light

2x1.5mm

2

30m

C: Photocell

4x0.5 mm

2

30m

D: Pushbutton/wall key

2x0.5 mm

2

25m

E/F: Operator / Limit switches

3x1mm

2

/ 3x0.50mm

2

8m

G: Antenna

Coaxial cable 50

k

 (RG-58/U) 5m

Elements of the complete installation

MS

A-118/00  

–  201

9/

0

2

/12

firmw

are V1.00 o

later