INSTALLATION INSTRUCTION FOR PIR-150

2824-00002

         Page 

9

Annex 2:

Instructions for Terminating Screens and Ground Surface

Introduction

The detection range of a PIR detector is not limited but a function of size, speed and temperature contrast
of a target against its background. Alignment of the detectors should be carried out in such a way that the
field of view is terminated by a natural or artificial background at the end of the range. Reflections from
inside or outside the field of view have to be avoided as well as possible.

Definition of Field of View

The numbers stated in the technical manual for the vertical and horizontal dimensions are defined – per the
usual standards – as the half power points representing 50% of the relative sensitivity at that distance for a
typical human target. Absolute signal amplitudes depend on temperature contrast, speed and size of a
target and can be up to 20 times (and more for large vehicles) higher than the alarm threshold. For a strong
signal the dimensions will appear to be increased compared to the nominal values. This needs to be
considered when dimensioning a terminating screen.

Dimensioning a Terminating Screen

From the field of view definition it becomes clear that the width of a terminating screen has to be larger
than the actual figures given in the technical manual, this particularly when a street crosses the field of view
behind the screen.

A practical factor for the width of a screen is 

1.5 times the width Y

 of the field of view at the distance

from the detector.

The considerations for the vertical dimension are similar although a certain installation flexibility is given by
tilting the unit slightly downward with the risk of losing sensitivity in the uppermost part of the curtain.
Therefore it is recommended to extend the screen also vertically in the same way using the same factor of

1.5 times the elevation Z

.

Example

:

Screen at 100 m for a curtain height of 4 m with a PIR-150 (see Table 1)

Width Y

2.5 m

Screen Width

3.75 m

Elevation Z

2.0 m

Screen Height Above Axis

3.00 m

Total screen height = curtain height - elevation Z + screen height above axis

This results in 

minimum

 dimensions of 

3.75 m wide

 

by

 

5.0 m high 

(4.0 m - 2.0 m + 3.0 m) for the

terminating screen.

0

20

40

60

80

100

1 m

2 m

3 m

4 m

m

Z

Axis

Typical side view of a terminating screen in 100 m distance from the detector. The dimension „Z“ is app.
2.0 m corresponding to the value of the table in section 5.

Содержание PIR-150

Страница 1: ...cover It must be tightened to the point where it cannot be closed further with reasonable force There will then be hardly any gap between the cover and the housing considerably less than 0 5 mm The c...

Страница 2: ...ylic are suitable materials Effectiveness of a screen has to be checked by walk testing around the screen Signals from walk tests in front of the screen should still be strong while movements behind t...

Страница 3: ...ensitivity of the PIR 150 by increasing the alarm threshold level or may lead to unwanted alarms Top view Fig 2 The ZA P 03 alignment telescope is a convenient alignment aid giving a high degree of ac...

Страница 4: ...eed at the end of the range will produce relatively weak signals 7 Alarm Time The alarm time depends on the shape and amplitude of the alarm signal and can be as short as app 0 2 s If a signal is very...

Страница 5: ...ate the PIR 150 with the heater connected as temporary loss of sensitivity or permanent damage could result from condensation inside the detector 11 Installation Tester IT 44 The Installation Tester I...

Страница 6: ...een optimised for the detection of human size targets crossing the field of view in an upright position at speeds in the range of 0 2 5 0 m s Detection of slow moving targets at long range may become...

Страница 7: ...inal Temperature Compensation Gain control 40 100 Target Speed 0 2 5 m sec Internal Switches Adaptive threshold system on off Supply Voltage 10 5 to 28 VDC nominal 12VDC Supply Current Typ 20 mA at 12...

Страница 8: ...N FOR PIR 150 Page 8 2824 00002 Annex 1 Connector Board and Terminal Block The relay is shown in energised non alarm state ATD is activated when switch is open close switch for walk tests only Connect...

Страница 9: ...ating screen Dimensioning a Terminating Screen From the field of view definition it becomes clear that the width of a terminating screen has to be larger than the actual figures given in the technical...

Страница 10: ...s from the rising or setting sun which may generate strong signals together with fast moving clouds In cases where the screen is facing sunrise or sunset at any time of the year the top of the screen...

Страница 11: ...44 including its version e g V 0 2 on line 1 as well as Analog Mode on line 3 for a short period of time The same display will appear every time RESET is pressed Liquid Crystal Display The display is...

Страница 12: ...either by adjusting the alignment and or sensitivity of the detector or by removing disturbance sources from within the field of view PIRScope Software for PIR 150 For Display of Signals on a PC Scree...

Отзывы: