PIR-045

PASSIVE INFRARED DETECTOR

2800-00006                                                                                                                                                                                       Page 9 of 10

Annex 3:

Installation Software

Introduction

The installation software is available as accessory for alignment, setting up and fault finding and can be used with all

detectors of the IR 450 Series. It is recommended for verification of all installations in order to optimise the performance of

the detectors and can be used for remote programming and verification of all detectors connected to the same RS 485 data

bus.

A converter RS 232 to RS 485 is required for operation with a standard PC.

The following describes the features of the installation software program for remote program ming and signal display.

Application of the Installation Software

The installation software is a most useful tool for checking the alignment and sensitivity setting of the detectors. It greatly

facilitates the optimisation of an installation to suit a particular site.

The software is particularly helpful in situations where a detector is operated under conditions near the recommended

operating limits of height, detection range and target speeds. The information supplied by the PC display should be used to

monitor the detection performance of the detector and make adjustments if required.

Depending on the site’s animal activity, vegetation moving in the wind and/or other sources of disturbance it is possible that

unwanted alarms occur. Monitoring and interpreting the information supplied by the installation software will help finding the

best solution either by adjusting the alignment and/or sensitivity of the detector or by removing disturbance sources from

within the field of view.

Installation Software for PIR-045

Procedure

 

Connect the PIR-045 to power and connect the interface module to the detector’s test socket or the terminal block as
defined in annex 1.

 

Connect the output of the interface module with the serial COM port of the PC

 

Exit „Windows“ and 

start PC under DOS

 

Load file installation program (INST45XC.EXE), enter language and number of COM port

Main Menu IR 45X

The Main Menu offers the following options:

[F1]

Scanning (range 1 … 20)

 

Pressing 

[F1]

 initiates a search for all detectors with different ID numbers within the defined range, which are connected

to the same RS 485 data bus.

 

After successful search all detectors found are listed in the table with their model, and version.

[F2]

Scan Range (any value from 1 … 254 for start and stop addresses)

 

Depending on the ID numbers of the detectors, the start and stop addresses can be varied.

[F3]

Configuration (Remote Programming)

Fore remote programming the 

DIP - Switches 1 and 2

 need to be set to position „

on“

 

Press 

[F1]

 and select the detector to be programmed using the arrow keys.

 

Adjust the parameters as required within the range indicated on the display.

Содержание Eagle PIR-045

Страница 1: ...nwanted alarms The universal bracket is equally suited for wall mounting using screws or pole mounting using steel bands through the slots It is very important that the cover of the PIR 045 is securel...

Страница 2: ...the field of view is terminated by a natural or artificial background at the end of the range Vertical alignment is optimal when the upper edge of the field of view is at 1 5 to 2 5 m above ground at...

Страница 3: ...n be reset by pressing n Alternatively the threshold level can be kept to its minimum value by changing the configuration of the ATD for this test see annex 3 for details Sensitivity Settings The vari...

Страница 4: ...his detector model Alarm Time Alarm time and count per event is determined by the duration of the detected event and depends on the shape and amplitude of the alarm signal Individual alarm pulses have...

Страница 5: ...ult of RF interference lightning shock waves or birds flying across the field of view close to the unit a possible alarm will be rejected This means also that a very fast movement directly in front of...

Страница 6: ...s cannot be achieved masking of the PIR 045 cannot be excluded Detection is a function of thermal contrast speed and size of a target crossing the field of view Contrast conditions can vary significan...

Страница 7: ...Night OFF Memory set enable LED disable Day OFF If memory was set LED flashes 2 Hz Day ON Walk test indication LED enable Night ON X Memory reset LED stop flashing B A Cover switch Day Night Not used...

Страница 8: ...Configuration For this the use of the interface module PIR IF485A is recommended see section 12 above The test socket carries V GND and the two RS 485 ports A and B The detector needs to be opened fo...

Страница 9: ...ation moving in the wind and or other sources of disturbance it is possible that unwanted alarms occur Monitoring and interpreting the information supplied by the installation software will help findi...

Страница 10: ...l be generated and saved as DDMMYYAB BMP where AB is used for identification of files within one day This function is not possible when the display is frozen n to reset the thresholds to the minimum v...

Отзывы: