background image

4

Specifications

Specifications

Description

Parameter

Min.

Typ

Max.

Unit

Note

Inputs

Mains

207

230

253 VAC

104

115

126 VAC

Control  (ERNA)

2,5

12 V

pp

Outputs

Control (ERNA)

6

V

pp

Lens Voltage

6

12 VDC

Lens Current

150 mA

per function.

Pan/tilt Voltage

250 VAC

Pan/tilt Current, total consumption

2 A

total, fused.

AUX 1 - AUX 2 voltage

250

24

VAC
VDC

AUX 1 - AUX 2, max. current

5 A

NOT fused.

General

Power consumption,

5 VA

Temperature range

-15

55 º C

Relative humidity

95 %

Comply to

EN 50081-1
EN 50130-4

EN 60950

EMC

Safety

Enclosure

IP 65

ABS box.

Dimensions excl. cable glands

250 x 160 x 90

mm

Weight

1,2 Kg

HEAD OFFICE: ERNITEC A/S, HØRKÆR 24, P.O. BOX 720, DK-2730 HERLEV, DENMARK

TELEPHONE: +45 44 92 30 00, TELEFAX: +45 44 92 72 82

UK OFFICE: ERNITEC UK, GERRARD HOUSE, WORTHING ROAD, EAST PRESTON, WEST SUSSEX BN16 1AW, ENGLAND

TELEPHONE: (01903) 77 27 27, TELEFAX: (01903) 77 27 07

GERMAN OFFICE: ERNITEC GmbH., STORMARNRING 28, 22145 STAPELFELD, GERMANY

TELEPHONE: (040) 675625 0, TELEFAX: (040) 675625 25

FRENCH OFFICE: ERNITEC FRANCE, PARC PEREIRE, 95 RUE PEREIRE, BAT. D, 78100 SAINT GERMAINE EN LAYE, FRANCE

TELEPHONE: (1) 39 21 12 00, TELEFAX: (1) 39 21 12 95

Installation Manual

Page 12

3020-00025

Содержание BDR-510/2

Страница 1: ...Installation Instruction for BDR 510 2 BDR 514 2 Digital Camera Stations 3020 00025 98 02 19...

Страница 2: ...between 230 VAC and 115 VAC mains voltage The BDR 510 2 and BDR 514 2 is housed in an IP65 rated ABS box and can be used in connection with SYSTEM 500M and SYSTEM 1000M Besides the BDR 510 2 and BDR...

Страница 3: ...575 ICU 9 Show seq stack 0 Not used BDR 55x 10 Latch AUX 0 255 Bit 2 AUX1 3 AUX 2 4 AUX 3 5 AUX 4 6 AUX 5 7 AUX 6 Low Latch High No latch Not used BDR 55x 11 Sequence dwelltime 0 255 Seconds Not used...

Страница 4: ...rm 2 0 Off 1 On 4 Alarm 1 priority 0 Low 1 High 5 Alarm 2 0 Low 1 High 6 Alarm 1 0 Disable 1 Enable 7 ALarm 2 0 Disable 1 Enable ICU 3 Alarm 1 Set up 0 255 Bit 0 5 Preposition 6 Relay 1 0 Disable 1 En...

Страница 5: ...order to avoid damage on the equipment Warning Make sure the equipment is earthed otherwise the over voltage protection will not work 2 3 Cable connections It is of utmost importance that all cable c...

Страница 6: ...ducted by the connected wires or transmitted as electromagnetic fields Electromagnetic noise can cause malfunction or damage to the equipment The Series BDR 510 2 BDR 514 2 are tested and fulfils the...

Страница 7: ...4 Y5 Y6 Y7 Y8 Y9 Y10 Y11 Y12 Y13 Y14 Y15 Y16 Y17 Y18 Y19 Y20 MAINS CTRL 0498 00026 rev 0 1 ernitec ACHTUNG DANGER ACHTUNG DANGER X1 X2 X3 X4 X5 X6 X7 SELECT OUT IN LENS IC IO FF FN ZT ZW AUX2 AUX1 P T...

Страница 8: ...OUT IN LENS IC IO FF FN ZT ZW AUX 2 AUX 1 TD TU PR PL L PE MAINS IN MAINS OUT PE L N L N A A B B CTRL P T Tilt Down 4 Pan Right 2 Pan left 1 EARTH 7 NEUTRAL 6 Tilt Up 3 Figure 4 Pan Tilt connection Th...

Страница 9: ...IO FF FN ZT ZW AUX 2 AUX 1 P T TD TU PR PL L PE MAINSIN MAINSOUT PE L N L N A A B B CTRL Figure 7 Connection of motorised lens 2 4 6 ERNA Camera control input connection The ERNA signal is connected t...

Страница 10: ...tch SW1 Description 1 2 3 4 5 6 Address number 0 ON ON ON ON ON ON Address number 1 ON ON ON ON ON OFF Address number 2 ON ON ON ON OFF ON Address number 3 ON ON ON ON OFF OFF Address number 4 ON ON O...

Страница 11: ...OFF OFF ON ON OFF Address number 26 ON OFF OFF ON OFF ON Address number 27 ON OFF OFF ON OFF OFF Address number 28 ON OFF OFF OFF ON ON Address number 29 ON OFF OFF OFF ON OFF Address number 30 ON OFF...

Страница 12: ...1 EN 50130 4 EN 60950 EMC Safety Enclosure IP 65 ABS box Dimensions excl cable glands 250 x 160 x 90 mm Weight 1 2 Kg HEAD OFFICE ERNITEC A S H RK R 24 P O BOX 720 DK 2730 HERLEV DENMARK TELEPHONE 45...

Страница 13: ...JAPAN OFFICE ERNITEC JAPAN LTD 8 16 GAKUEN HIGASHIMACHI 1 CHOME KODAIRA SHI TOKYO 187 JAPAN TELEPHONE 0 423 466290 TELEFAX 0 423 465646 Installation Manual 3020 00025 Page 13...