2.1
Box installation
Choose a plain surface to prevent the box from being twisted and thereby becoming leaky while
mounted. When mounted out-door the box should be oriented with the cable glands pointing
downwards.
Screws and wall plugs are supplied in the mounting kit. Drilling dimensions are shown on the
figures at the end of this manual.
2.2
Mains installation
The BVT-225, BVR-225 and the BVX-225 can be supplied with either 115 VAC or 230 VAC mains
voltage. The mains voltage is selected by the mains voltage change-over switch, refer to the
figures. The connection of the mains cable is also shown on the figures.
Terminals marked with hazardous live symbol requires installation by an instructed person.
The BVT/R/X-225 must be used with a 3-wire mains connection (2W+PE @ min. 0,75mm2).
Details on the mains supply can also be found on a label fitted inside the lid of the BVT/R/X-225.
Terminals marked with hazardous live symbol requires installation by an instructed person.
If permanently connected to mains, a readily accessible disconnect device shall be incorporated in
the building installation wiring.
If pluggable connection to mains, the socket-outlet shall be installed near the equipment and shall
be easily accessible .
In order to fulfil the safety standard (IEC 60950), the mains cable must be routed via the provided
cable clip inside the Series 225 box. Figure below shows how the mains cable should be routed.
Warning:
Before connecting the unit to the mains outlet make sure that the mains voltage
change-over switch is set for correct mains voltage in order to avoid damage on the equipment.
Warning:
Make sure the equipment is earthed; otherwise the over voltage protection will not
work!
Although both the transmitter and the receiver are earthed no ground loop problems will
occur due to the galvanic separation of the video signal introduced in the transmitter.
2.3
Video cable connections
Connect the cables exactly as shown on the figure. The unbalanced outputs on all three units can
be used simultaneously.
Note:
If any of the unbalanced outputs are unused make sure to leave the factory fitted
termination load in position for optimum performance.
Warning
: At the transmitter end do not in any way connect the twisted pair shield. If the shield is
connected to the transmitter the galvanic separation will not work!
The shield should be connected at the receiver end only.
Twisted pair video equipment Series 225
2800-00054
Mains terminal block
Cable clip
Mains cable
Mains cable