05.1

Technical details

Electrical Properties

MIDI OUT 

The midiclock has two MIDI ports (DIN, 5-pole). They provide a current 
loop and are designed for opto-coupler driven slaves, like documented 
in the MIDI specs. The no-load voltage is 3.3V, the short-circuit current 
is 20mA.

Power

The USB port (Type B) acts only as a power supply. You can use either 
a computer or an external power adaptor. The power consumption is 
max. 75mA at 5V when used properly. 
Please note that the input voltage must not exceed 7V under any 
circumstances.

Dimensions and Weight

The dimensions with knob and rubber feet are 48mm high, 95mm long 
and 62mm wide. The weight is 235g without cable.

05.2

Table of MIDI commands

The midiclock uses the following MIDI commands to synchronise and 
control all connected slaves:

The MIDI clock command (0xF8) is always being sent when a power 
supply is connected. The jitter is 0.1µs on average, the maximum devi-
ation is 0.46µs.

          Function  

 

 

  MIDI command

Synchronisation         MIDI clock:               

          0xF8

Start                               Song Position Pointer:              0xF2, 0x00, 0x00
                                        MIDI start:                                     0xFA
Pause                             MIDI stop:                                      0xFC
Continue                       MIDI continue:                             0xFB
Reset                             like 'Start' 
Resync                           like 'Start', but on the next downbeat

Содержание midiclock

Страница 1: ...Manual midiclock Function Utilization and technical Details ...

Страница 2: ...3 2 Modes of Operation 04 Hints for Synchronisation with MIDI clock 05 Technical Details 5 1 Electrical Properties Dimensions and Weight 5 2 MIDI command Reference 06 Operating Notes 07 Declaration of Conformity 08 Contact 02 03 04 05 06 09 10 11 13 14 15 16 17 18 19 Simply play together ...

Страница 3: ...rfor mance or improvisation It s easy now to sync multiple DAWs and sequencers with a uniquely low jitter control the tempo and start and stop your gear whenever you want The midiclock opens up new possibilities for you to interact with other artists Please read this manual carefully and follow the advice to be rewarded from the beginning with a great and powerful tool Have fun and simply play tog...

Страница 4: ...s if necessary so that they can sync to MIDI clock USB USB FW Computer If you use a software sequencer please adjust the correct settings to compensate the latencies For further information please consider chapter 04 Hints for synchronisation with MIDI Clock Set your required tempo with the rotary encoder and confirm by pressing it down If all devices are connected and ready for playback you can s...

Страница 5: ...stantly lit when paused and turns off if all devices are reset at the next beginning of a playback 02 Rotary encoder The rotary encoder is used to set the tempo The respective function depends on the current operating mode In the Live mode tempo changes are applied immediately In the Normal mode the tempo is only changed if you press down the encoder after your setting You can switch between both ...

Страница 6: ...Continue are sent alternately 04 Resync Reset Button If pressed during playback this button causes a reset of the song position pointer in all connected devices at the beginning of the next bar followed by MIDI Start With this feature you are able to re sync slaves during playback without interruption If it is pressed while the playback is paused it acts like a Stop button If you now press Play ag...

Страница 7: ...mpo at any time during the playback In this case the tempo changes are applied immediately and without confirmation During Live mode the BPM shown in the display is always the actual tempo You can always get back into the Normal mode by double clicking the encoder again 04 Hints for Synchronisation with MIDI clock Synchronising multiple MIDI devices is a known topic for almost any electronic music...

Страница 8: ...ognize some sort of a run out time In this run out time the data in the audio buffer is played till the end and the playback does not stop immedia tely This causes that some sequencers do not stop instantly with the arrival of the stop command but with delay of the buffer If now the master does not define a new song position the slaves are shifted to each other on a continue command In this case a...

Страница 9: ... voltage must not exceed 7V under any circumstances Dimensions and Weight The dimensions with knob and rubber feet are 48mm high 95mm long and 62mm wide The weight is 235g without cable 05 2 Table of MIDI commands The midiclock uses the following MIDI commands to synchronise and control all connected slaves The MIDI clock command 0xF8 is always being sent when a power supply is connected The jitte...

Страница 10: ...ent time before you use your midiclock Otherwise there may be condensation which can destroy the electronics inside The midiclock must not be used in wet environments and the ingress of any fluids must be avoided Usually the power is supplied by a computer USB port If you want to use a wall plug be sure to meet the electrical specifications Damages which are caused by third party wall plugs are no...

Страница 11: ... dispose your midiclock please contact your local dealer for recycling Do not put it in your household waste RoHS 08 Contact We that is Erfindungsbüro Rest Maier made the midiclock meet our own high expectations on value and functionality of a product If you have any questions or suggestions do not hesitate to contact us A small production batch for professional users makes it possible to adapt to...

Страница 12: ...Composition and Layout Aaron Winter Contributing editors to the English version Matthew Thomas and Kathrin Schalper Erfindungsbüro Rest Maier GbR Berlin 2013 www midiclock de ...

Отзывы: