Erlab’s state of the art Research & Development Laboratory relies exclusively on filtration

1

 Erlab R&D Laboratory

 

The engineers and chemists in our state-of-the-art R&D laboratory understand molecular 

filtration. We are committed to designing products that are safe and of the highest quality, 

strive  to  improve  our  products,  and  continuously  develop  new  products  that  provide 

greater protection in the laboratory.

2

 Strict Safety Standards

 

We hold ourselves to the highest standard and adhere to the strict AFNOR NF X 15-211: 

2009 filtration safety standard as endorsed by ANSI Z9.5-2012.

3

 A Published Chemical Listing

 

It all begins here. Without this listing, we are not compliant with AFNOR NF X 15-211. Our 

in-house laboratory tests, as well as independent testing, to verify the retention capacity 

of over 700 chemicals for our filters.

4

 Independent Testing

 

Erlab  filters  have  been  independently  tested  multiple  times  at  various  concentrations 

guaranteeing that our safety solutions all adhere to the strict performance criteria of the 

AFNOR NF X 15-211:2009 standard assuring that the emission concentration at the filter 

exhaust will always be lower than 1% of the TLV.

5

 Application Questionnaire (Valiquest)

 

Our laboratory specialists will recommend the appropriate filtration fume hood, type of 

filter, and personalized advice.

6

 Certificate of Validation for the chemicals used in the hood

 

A  certified  PhD  chemist  issues  a  Certificate  of  Validation  with  a  list  of  the  chemicals 

approved for use in the hood.

7

 Our Safety Program

 

We  back  up  our  products  100%.  This  program  includes  your  specialized  chemical 

evaluation, validation of your hood upon installation, and a filtration safety specialist at 

your service to ensure that your hood is operating to its full potential during it’s entire 

lifetime of use.

About Erlab

About Erlab

Erlab above

We provide safety, we protect your health

Erlab invented the ductless fume hood in 1968. With more than 50 years of experience in the 

field of chemical filtration and protection of laboratory personnel; we know the formula for 

safety. With Erlab, you will never have to wonder or worry if our products are safe. We build 

each one of the following 7 very important safety features into our products. Without all of 

them, your health and safety will be compromised.

France 

+33 (0) 2 32 09 55 80 │ [email protected]

United States 

+1 800-964-4434 │ [email protected]

China 

+86 (0) 512 5781 4085 │ [email protected]

Malaysia  

(+603) 6419 4514 │ [email protected]

Germany  

0800 330 47 31│ [email protected] 

United Kingdom 

 +44 (0) 1722 341 940 │[email protected]

Italy 

+39 (0) 2 89 00 771 │ [email protected]
 

Spain 

+34 93 673 24 74 │ [email protected]

             www.erlab.com

Содержание Captair Flow Smart

Страница 1: ...Safer Simpler User manual Captair Flow Smart Mobile ductless filtering clean air enclosure ...

Страница 2: ...ule Description of the alarms eGuard App 6 Connectivity principle Options of connection Accessing the Administrator interface Administrator interface description Fan setpoints per filtration column type 15 Replacing the filters 16 Recommendations for storing and using the filters 20 Replacement frequency for filtration breakthrough sensor Molecode option 21 Admissible weighs on worksurfaces 21 Cle...

Страница 3: ...sitioned correctly Erlab recommends that the electronic anemometer is calibrated at least once a year New filters must be stored in their packaging kept in a dry location see recommendations for storing and using the filters Product registration Take full advantage of the device s connectivity to enhance your safety Get up to 10 years warranty on your connected Erlab unit Register your product onl...

Страница 4: ...dy to be turned on 4 To operate push the power button located on the front control panel Good practices Avoid any air turbulence in the area during calibration Anemometer should be calibrated every year and every time a modification is done on the filtration column Having carefully followed the steps described in the installation guide your Captair Flow Smart ductless filtering clean air enclosure...

Страница 5: ...Please access the administrator interface to verify user settings Alarm type Light signal Problem Details Silence the alarm Reset the alarm Air speed 1 beep 5 seconds apart Pulses Low air speed The air speed value is 0 3 m s Press Mute key Please check the front sash is correctly closed Check particulate filter If the filter is not clogged up perform a new calibration of the anemometer with door o...

Страница 6: ...ff position located on the left side of the controller 2 Turn the power switch to the On The Primary IP address to use is 192 168 0 200 Note In some cases you may need to use the secondary IP address 192 169 0 200 eGuard App Welcome to a safer connected world The connectivity of Erlab Smart devices allows you to monitor all your safety settings remotely After registering your product on line downl...

Страница 7: ...connected to Internet or local network Parameters Monitoring Controlling Monitoring Monitoring Controlling Data access One unit Multiple units Multiple units Historical data access Historical data download Alerts Monitor multiple devices Allow multiple user accounts Automated status report Download available on www erlab com Options to connect Embedded service RJ45 Mobile or computer app and or In...

Страница 8: ... to the computer is provided 1 Direct connection on computer Check that main switch of the device is ON Take RJ45 cable black is already connec ted to the unit and placed behind the back of the control panel 2 Open your web browser type the following IP address 192 168 0 200 into the address bar and validate OK You are connected to the embedded software You enter the Status page and you can have a...

Страница 9: ...9 Page is not accessible 3 Modify computer network parameters Right click Left click Network parameters 4 Access to the Network and sharing center Left click ...

Страница 10: ... filtering clean air enclosure 10 5 Access to the network connection Right click Left click to access properties Note This confirms your WIFI is disconnected 6 Enter compatible network parameters as indicated below Left click Left click ...

Страница 11: ...the operation Enter the following parameters Validate 7 Open your web browser again type again the following IP address 192 168 0 200 and validate OK You are connected to the embedded software You enter the Status page and you can have access to the Settings using the following cre dentials Login erlab Password smart ...

Страница 12: ... 1 Choose active interface page 2 Device ID Model 3 Device ID serial number MAC address device status 4 Unit location 5 Molecode Option Gauge indicates the sa turation level of the main carbon filter s 6 Fan Gauge Indicates the fan status 7 Device use time since fan was last started 8 Device alarm statuses see alarm triggering conditions 9 Volume setting 10 Embedded service version 11 Choose langu...

Страница 13: ...13 1 5 2 3 4 6 Access to the settings is protected by the following credentials User name erlab Password smart 7 ...

Страница 14: ...tivate the exchange of information This allows the transmission of information from the device to the eGuard server for remote monitoring via eGuard App mobile PC receiving usage reports 4 Device fan setpoint settings 5 Alarm saturation filter Molecode option Sensor type indication Solvents Sensor sensitivity settings 5 settings capteur S High sensitivity Medium High Sensitivity Medium Sensitivity...

Страница 15: ... Displays the device s event log 2 Used for downloading the log in csv format Fan setpoints per filtration column type Unit Type of filtration column 1P 1C1P 321 2800 RPM 2100 RPM 391 483 2200 RPM 2200 RPM 714 2100 RPM 2100 RPM ...

Страница 16: ...he device is first set up If so please contact us so that we can verify that the current configuration is safe or it needs to be reconfigured The table below summarises all possible Flex filter technology configurations for your device Captair Flow 321 391 Smart models Molecular filter Particulate filter Pre filtre Column Configuration 1P x1 x1 1C1P x1 x1 Captair Flow 483 714 Smart models Molecula...

Страница 17: ...the spray to dry 4 Shut down and unplug the device and disconnect the fan module power supply cable and the sampling tubes from the sampling area if installed 5 Carefully remove the molecular filter s if present and the fan module 6 Carefully unwrap the new HEPA ULPA filter Keep the plastic film and cardboard box so that you can use it later to pack up the used filter Lay out the film on a flat su...

Страница 18: ...recommended that the user or service en gineer wears the necessary safety equipment including safety glasses lab coat and gloves Switch off the workstation Remove the covers from both sides or front of the workstation Disconnect the power supply to the fan Example Captair Flow 483 Smart Example Captair Flow 321 Smart A i r F l o w ...

Страница 19: ...ck the filtration column s above the workstation After carrefuly removing the filters from their packaging assemble the column per the configuration below If your column configuration changed Apply the correct fan setpoint for the filtration column configuration see fan setpoints Models Captair Flow 483 714 Smart 1P 1C1P 1P 1C1P ...

Страница 20: ...eir original packaging at a temperature of between 10 C 50 F and 50 C 120 F and a humidity level 85 RH HEPA H14 and or ULPA filters must be stored upright and kept dry If these conditions are respected the maximum time a filter can be stored before use depends on the type of filter AS type carbon molecular filter 1 year from the date of delivery HEPA ULPA filter 2 years from the date of delivery I...

Страница 21: ...onents and perform system new configuration The change requires less than one hour Erlab Maintenance department and accredited partners can provide this service service not available in all countries For further information please get in touch with your contact person or Erlab dealer distributor or visit our website Admissible weights on worksurfaces The chart below reflects loads that are evenly ...

Страница 22: ...closure Cleaning the enclosure The enclosure must be cleaned on a regular basis This may be accomplished in several ways With soapy water followed by rinsing with clear water and drying with a soft non abrasive absorbent paper towel Or with a commercial pH neutral product followed by drying with a soft non abrasive absorbent paper towel Or with a non alcoholic disinfectant detergent Coated metal p...

Страница 23: ...23 ...

Страница 24: ...the TLV 5 Application Questionnaire Valiquest Our laboratory specialists will recommend the appropriate filtration fume hood type of filter and personalized advice 6 Certificate of Validation for the chemicals used in the hood A certified PhD chemist issues a Certificate of Validation with a list of the chemicals approved for use in the hood 7 Our Safety Program We back up our products 100 This pr...

Отзывы: