ERL aco COMO PRO Скачать руководство пользователя страница 2

www.electroreplacement.com

UK Sales & Technical Support

TEL: 01923 255 344
[email protected]

ACO Technical Support

www.support.aco.com.pl
www.aco.com.pl

UK Distributor of 

ACO products

E&O.E.

PRO3 Manager PC Software

The PRO3 Manager PC software allows full control of the panel 
and handset/monitors. The software is free to download and will 
work on all windows 7, 8 , 10 laptop / PCs.  Drivers may need to be 
installed. Once connected you will be able to easily con

fi

 gure:

•  Key fobs (adding and removing) 
•  Receiver addresses and description
•  ELOCK OUTPUT settings: Electric Lock, Reverse, Relay 
•  Door activation/opening times from 0.6 to 25secs.  Default time 

is 4sec

•  Door opening delay (from the moment the exit button is 

pressed to the actual opening of the door from 1 s to 25s) 

•  Individual DEV ID numbers of each panel
•  Compatible with earlier PRO systems
•  Additional panels within one system, e.g. Master and 

Secondary Panels.  (Switching camera views the switch module 
VIDEO-SW2 MINI 60  is required

•  Individual handset/monitor volume and ring type
•  Brightness and colour parameters

Additionally you can: 

•  Save and load con

fi

 guration 

fi

 les

•  Save to Drop Box and Google Drive

Cable Requirement 

•  Connecting the panel, power supply and receivers together 

is recommended using CAT5e cable or higher into the RJ45 
sockets to ensure optimal transmission, especially for video 
image or distortion may occur

•  If other types of cables are used tests should be completed to 

ensure proper operation of the system

•  RJ45 CAT5e is the easiest way to connect a panel but a 

successful setup can also be achieved using the ARK screw 
terminals and following the T568B standard diagram 

•  All cables must be clamped in line with the T568B standard

Cable Distances:

The maximum cable run length between:

•  The panel and power supply is 100m
•  The receivers inside unit and power supply is 70m 
•  Distances over 100m an additional power supply should be 

used

It is possible to extend the distance by increasing the cross section 
of wires, using thicker wires and an additional power supply. If 
a distance other than those speci

fi

 ed should be tested in a trial 

situation and checks on the whole system should be carried out. 

NOTE:

 Avoid routing cables (especially the signal ones for: Audio/

Video) in close proximity to the cables of other installations (power, 
telecommunication, alarm systems) as this may adversely a

 ect the 

operation of the system.  