9
Trouble shooting:
error
machine not ready to use,
no display in the touchpanel
heating does not switch on
program reacts absurdly
absurd temperature
indication
vacuum not sufficient
vacuum pump does not
function
automated thermoforming
action clamps
” ” ”
foil reception moves
upwards again (Error 001)
possible reason
wall socket, machine plug or
fuses defective
foil reception not in the
correct position
heater, switch for heater or
circuit board defective
system crash,
program faulty
sensor window soiled,
sensor defective
granules on the sealings,
hole in the foil, sealings
used, vacuum pump soiled or
defective
membrane clotty,
menbrane too hard at room
temperature below 15 °C
attachment got stuck
foil reception not correctly
positioned under the heating
motion area not free
elimination
(after sales service = ass)
check wall socket, machine
plug, fuses (at the machine plug)
foil reception has to clearly click
into place under the heating,
exchange heater, switch for
heater or circuit board (ass)
switch machine on and off,
deploy program again (ass)
clean sensor window,
exchange sensor (ass)
remove granules from sealings,
check foils concerning holes,
exchange sealings, clean or
exchange vacuum pump (ass)
clean membrane (ass)
allow machine to warm up for
app. 2 hours at room tempera-
ture to avoid condensed water
switch machine off, wait for 5
seconds, switch the machine on
again, swivel foil reception up to
the right
restart thermoforming process
and turn foil reception in the
engagement position under the
heating
do not reach into the motion
area and keep it free