erkodent Erkoform-3dmotion Скачать руководство пользователя страница 1

Erkodent

 

Erich Kopp GmbH

 

• Siemensstraße 3

 

• 72285 Pfalzgrafenweiler

 

• Germany

Tel.: +49 (0) 74 45  85 01-0

 

• Fax: +49 (0) 74 45  20 92

 

• www.erkodent.com

 

• [email protected]

Erkoform

-3d

motion

 

               

Medium-wave infrared 

heater with cover

Form pot for reception of 

granules pot, model plate 

and Occluform-3 model pot

(Occluform-3, 188 580)

Foil reception handle with

cavity for good grip

Column for movement of

foil reception 

Sensor window for 

temperature registration

Mains connection (back)

Foil reception with

foil securing ring

Main switch

Touchpanel to operate all

functions

Granules collecting device

Erkoform-3d

motion

Vacuum thermoforming 

unit with touchless 

temperature control

(EP 1 905 380),  

pre-vacuum, touchpanel  

and automated 

thermoforming process

Model plate* for very flat trimmed models

*

also included

Granules pot*, 

Ø

 inside 97 mm

height inside 40 mm

Instructions

Содержание Erkoform-3dmotion

Страница 1: ...ion handle with cavity for good grip Column for movement of foil reception Sensor window for temperature registration Mains connection back Foil reception with foil securing ring Main switch Touchpanel to operate all functions Granules collecting device Erkoform 3dmotion Vacuum thermoforming unit with touchless temperature control EP 1 905 380 pre vacuum touchpanel and automated thermoforming proc...

Страница 2: ...s To ensure that the unit maintains its full function the sealing rings require replacing once a year when the unit is consistently in use New seals should be firmly pushed into position Installation instructions In order to avoid humidity and dirt entering the unit install and store it in a dry and low dust environment Allow a cold unit after transportation storage or similiar to warm up for 2 ho...

Страница 3: ...ow A dirty sensor window leads to mea surement errors If necessary dust off or clean with a damp cloth no clean ing agents After a few seconds the basic display automatically appears The touchpanel responds in the framed function fields on slight pres sure sensor window main switch 2 refer to instructions main menue foil thickness risk of crushing continue foil temperature list of foils back cooli...

Страница 4: ...an be used with this machine and that have been available at the time of production of this unit Add new foil page 6 Save favourites page 5 1 Select list of foils 3 Select 1 0 mm 2 Select Erkodur 4 Selected foil 3 Thumb list of foils back menu continue Functions of this indication selected foil rated temperature cooling time work with Occluform 3 change rated tempera ture and cooling time save as ...

Страница 5: ...eating the display shows the foil temperature 70 C before the rated temperature is reached the vacuum pump switches on to built up the pre vac uum 3 Attention Thermoforming pro cess 10 C before the rated temperature is reached there will be an audibly and visual warning of the automated thermo forming process Attention risk of crushing Do not reach into motion area 4 Cooling time After the thermof...

Страница 6: ...having selected the desired foil from the list of foils the display 1 will be visible To save the foil as favourite select to favourites Recommendation If an Erkodent foil will be saved with the factory parameters and as a favou rite with changed parameters the changed one should be saved as new foil with a different name in order to avoid any mix up 1 Select add favourite 2 Confirm add favourite ...

Страница 7: ...e and the cooling time have to be determined with the help of the special functions The new foils will be saved in the list of favourites and selected via this list Hint Max 240 C can be entered as rated temperature The cooling time has to be at least 30 sec Otherwise there may be malfunctions 1 Select new foils 5 Enter cooling time 2 Enter foil name 6 Select favourite 3 Enter foil thickness 7 Sel...

Страница 8: ...ected foil or favourite also see select foil and save favourite 1 Select change 2 Change rated tem perature and cooling time 3 Thermoform or save as favourite Abort Save Thermoform once with the changed data Save as favou rite As favourite the changed data and the foil name will remain Optional Occluform 3 device 188 580 to imprint the opposing bite The construction is based on a Bonwill triangle ...

Страница 9: ...acuum pump off vacuum pump on a To check the thermoformability swivel the foil towards outside b and check with a blunt instrument If permanent impressions result generally the foil is ready for thermoforming The heating switches off if the foil is swivelled out of the heating area heating off is selected or the sensor measures 240 C The temperature shown on the display is the temperature measured...

Страница 10: ...tachment got stuck foil reception not correctly positioned under the heating motion area not free elimination after sales service ass check wall socket machine plug fuses at the machine plug foil reception has to clearly click into place under the heating exchange heater switch for heater or circuit board ass switch machine on and off deploy program again ass clean sensor window exchange sensor as...

Страница 11: ...cluform 8 Attention the automat ed thermoforming process starts Risk of crushing 11 Release foil securing ring remove the Occlu form model pot with the foil 3 Select Erkoloc pro 6 Continue thermoform ing swivel foil reception under the heating the working steps required before thermo forming will be shown in a repeating animation All animations will be stopped with the next working step 9 Animated...

Страница 12: ...brush for filling granules with rubber cap 188 530 can also be used as input pen 1 on off magnet red or green red 110 890 to collect filling granules green 110 891 1 power supply cable 188 001 1 filling granules 110 852 1 3 kg supplied with the Erkoform 3d motion 1 8 kg high grade steel filling granules magnetic with rounded edges 1 foil trial package 1 machine documents folder instructions thermo...