4.

Screw the adjustable plunger into the

backplate of the new electrical assembly.
Place the coil over the plunger and slide the
assembly, with the power cord at the bottom,
into the feeder body (see Figure 7).

5.

Replace the four bolts in the backplate, tune

the feeder as described in “Tuning by Plunger
Adjustment” and tighten down the locking
hex nut.

FIGURE 7

THE Hl-VI MAGNETIC DRIVE
CIRCUIT

Old-style electromagnetic equipment has an
inefficient attract-release type operation, where
a mass mounted on springs is attracted by a DC
electromagnet and returned to its original position
solely by the springs.  The new Hi-Vi method
incorporates a lifetime permanent ceramic
magnet and is operated directly from an
alternating current line.

In the Hi-Vi method, the spring-mounted mass is
alternately both attracted and repelled by an AC
electromagnet assisted by the springs.

N

S

N

N

S

AC
POWER
SUPPLY

POTENTIOMETER

ELECTRO-MAGNET

ARMATURE CONNECTED 
TO SPRINGS AND 
MOVING MASS

PERMANENT
MAGNET

FIGURE 8

Intermeshing a fixed polarity permanent magnet
with an alternating polarity AC electromagnet
eliminates the rectifier since you would have an
alternating attracting and repelling force as the
polarity of the electromagnet alternated.

It will be noted that the pole pieces of the permanent
magnet are intermeshed in the air gaps of an
electromagnet.  The polarity of the permanent
magnet is fixed; the polarity of the electromagnet
alternates at the line frequency.  We have shown
the polarity of the electromagnet as it would exist
on one side of the sine wave.  Note that both poles
of the permanent magnet are being attracted
toward the unlike electromagnet poles.  They are
also being repelled in the same direction by the
like electromagnet poles.  This results in four forces
accumulating to drive the armature in the same
direction.  It also results in closing the magnetic
circuit through the electromagnet providing a
magnetizing effect on the permanent magnet on
each side of the sine wave.  The demagnetizing
force is very minor for the attracting force and the
magnetic lines of flux would much prefer to be
attracted than repelled.  This always tends to place
the permanent magnet in a magnetizing circuit
regardless of where the AC current is on the sine
wave.  As the polarity of the electromagnet changes,
all of the forces are reversed and the permanent
magnet armature is driven in the opposite direction.

Содержание HS-5

Страница 1: ...enance Instructions ERIEZ MAGNETICS HEADQUARTERS 2200 ASBURY ROAD P O BOX 10608 ERIE PA 16514 0608 U S A WORLD AUTHORITY IN ADVANCED TECHNOLOGY FOR MAGNETIC VIBRATORY and METAL DETECTION APPLICATIONS VM 3805B VIBRATORY FEEDER MODEL HS 5 ...

Страница 2: ...z HS 5 Vibratory Feeder Careful attention to these requirements will assure the most efficient and dependable performance of this equipment If there are any questions or comments about the manual please call Eriez at 814 835 6000 for Vibra tory Feeder assistance 2001 ERIEZ MAGNETICS ALL RIGHTS RESERVED ...

Страница 3: ...l Connections 4 OPERATION AND MAINTENANCE 5 Tuning Guide 5 Tuning by Plunger Adjustment 6 Tuning by Replacing Springs 6 Tuning for Non standard Trays 7 Tuning for Different Conditions of Tray Loading 7 REPAIRS 7 Spring Replacement 7 Coil Replacement 8 The Hi Vi Magnetic Drive Circuit 9 TROUBLESHOOTING 10 PARTS 12 ...

Страница 4: ...ll wiring should conform to all applicable elec trical codes 1 Check the specifications of the power line to be certain that they are the same as those shown on the nameplate 2 Connect the black and white wires in the feeder power cord to the power source or to the terminals in the control box marked Output 3 Connect the green wire to the ground or to the lug provided in the control box 4 Connect ...

Страница 5: ...ions will void the warranty See Standard Tray Specifications TUNING GUIDE General Information The tuning means is provided solely for the purpose of mechanically tuning the unit with its tray to the desired vibratory displacement at full voltage HS 5 drive units supplied without trays are tuned by Eriez for use with a three pound 1 36 kg weight If supplied with a tray they are tuned for that speci...

Страница 6: ...he Feeder operating ideally on the normal side of its tuning curve should be borne in mind FIGURE 3 FIGURE 4 when making tuning adjustments to increase or decrease the displacement 1 To DECREASE the tray displacement DECREASE the stiffness of the tuning springs 2 To INCREASE the tray displacement INCREASE the stiffness of the tuning springs If decreasing or increasing the tuning spring stiffness h...

Страница 7: ...ng during tuning is permissible but must not be allowed during regular operation since damage to the feeder can result Operation and Maintenance cont Repairs SPRING CHANGE OR REPLACEMENT Although the non metallic springs used in the Feeder have outstanding life characteristics failure may eventuallyoccur especiallyifthedisplacementisgreater than normal The symptoms of such failure will be 1 Errati...

Страница 8: ... metal sleeve and at the outer surface of the cylinder possibly with some outward bulging of the elastomer FIGURE 5 4 In replacing the elastomer springs lay the unit on its side so that the chamfered ends of the spring holes are up After making sure that the holes and their chamfered ends are clean and free from obstructions lubricate the elastomer spring with a solution of water and 10 of liquid ...

Страница 9: ...nates the rectifier since you would have an alternating attracting and repelling force as the polarity of the electromagnet alternated It will be noted that the pole pieces of the permanent magnet are intermeshed in the air gaps of an electromagnet The polarity of the permanent magnet is fixed the polarity of the electromagnet alternates at the line frequency We have shown the polarity of the elec...

Страница 10: ...Electrical Connections Shockmount Deterioration Corrosive or Abrasive Material Product Variation NATURE OF PROBLEM TABLE 2 SERVICE CHART Troubleshooting 1 Misapplication Feeder too small Product difficult or impos sible to handle Impossible temperatures or at mospheres Impossible dimensional require ments Feeding requirements too precise or excessive Consult Eriez 2 Tampering or Changing of Base o...

Страница 11: ... and correct 11 Incorrect Factory Adjustment Seemaintenanceinstructions gapadjustments 12 Sympathetic Vibration in Other Equipment Check and correct 13 Contact with Other Equipment Check and correct 14 Line Voltage Variation Check and install voltage regulator if necessary 15 Blown Fuse or Circuit Breaker Check for short circuits and correct 16 Other Electrical Connections Check all connections an...

Страница 12: ...tal Detection Applications HEADQUARTERS 2200 ASBURY ROAD P O BOX 10608 ERIE PA 16514 0608 U S A Telephone 814 835 6000 800 345 4946 Fax 814 838 4960 International Fax 814 833 3348 Web Site http www eriez com e mail eriez eriez com MANUFACTURING FACILITIES IN AUSTRALIA BRAZIL CANADA INDIA JAPAN MEXICO SOUTH AFRICA UNITED KINGDOM UNITED STATES 901 5C SG DP ERIEZ MANUFACTURING CO PRINTED IN USA Parts...

Отзывы: