9. Incorrect Tuning
See maintenance instructions. To decrease
displacement and output use fewer or thinner tuning
springs. To decrease displacement and eliminate
striking, use more or thicker tuning springs.
10. Poor or Broken Weld on Tray
Check and correct.
11. Incorrect Factory Adjustment
See maintenance instructions
(Gap adjustments.)
12. Sympathetic Vibration in Other Equipment
Check and correct.
13. Contact with Other Equipment
Check and correct.
14. Line Voltage or Hz Variation
Check and install voltage regulator if necessary.
Check Hz on output side of control. Adjust back to
30 Hz per control manual.
15. Blown Fuse or Circuit Breaker
Check for short circuits and correct.
16. Other Electrical Connections
Check all connections and correct.
17. Corrosive or Abrasive Material
May require special tray. Consult Eriez.
18. Product Variation
If product density, moisture content or other
characteristics vary, customer should take own
corrective measures.
Troubleshooting