Planning the Site and Installation
Preparing for Installation
3-3
Electrical Specifications
Table 3-2 lists the electrical specifications for the SmartEdge 1200 router.
Table 3-3 lists the operating and inrush current (in amperes) at –48 VDC for active traffic cards.
Table 3-2
Electrical Specifications
Requirement
Value
Input voltage, nominal
-48.0 Vdc
Input voltage range
–40.0 Vdc to –57.5 Vdc
Total input power, maximum
3840 VA
Input power per feed, maximum
1920 VA
Input current rating per feed
40 Adc@–48 Vdc
Source DC power requirement
• Sufficient to supply the rated input current
• Local codes apply
Number of input feeds
4: 2 from battery plant A and 2 from battery plant B
Table 3-3
Operating and Inrush Current for Traffic Cards at –48 VDC
Component
Operating Current
Inrush Current
1
1. Inrush current occurs during power on or during the installation of a component in a powered-on chassis. Unless
noted, maximum duration is 4 ms.
ATM
Enhanced ATM OC-12c/STM-4c
4-port ATM OC-3c/STM-1c
1.80
1.88
4.98
4.96
Ethernet and Gigabit Ethernet
10/100 Ethernet
FE-GE (60-port FE, 2-port GE)
Gigabit Ethernet (first and second versions)
Gigabit Ethernet 3
Gigabit Ethernet 1020 (10-port)
Gigabit Ethernet 1020 (20-port)
10 Gigabit Ethernet
1.44
2.80
1.56
2.24
2.95
3.70
2.72
4.20
0.62
2
4.04
4.00
3
2. Maximum duration is 28 ms
3. Maximum duration is 20 µs.
SONET/SDH
OC-192c/STM-64c 2.72