  EMERGENCY POWER OPTIONS

CH1L -

AUTOMOBILE 

BATTERY 

EMERGENCY

POWER (120 Vac/60 Hz VERSION); Adds a
charger and power harness cabling. The automo-
bile battery is external to the base station cabinet
and is purchased separately by the customer for
field installation.

CH1M -

AUTOMOBILE 

BATTERY 

EMERGENCY

POWER (230 Vac/50 Hz VERSION) Same as
CH1L except for international version charger.

CH1R -

GEL CELL BATTERY EMERGENCY POWER
(120 Vac/60 Hz VERSION) Adds a charger,
power cable harnessing, and a gel cell shelf. The
four 12V 25 AH gel cell batteries are not included
in this option. Each of the batteries can be ordered
for field installation per drop ship index item,
V2401.

CHI -

GEL CELL BATTERY EMERGENCY POWER
(230 Vac/50 Hz VERSION) Same as CH1R ex-
cept for international version charger.

Copyright© April 1992, Ericsson GE Mobile Communications Inc.

TABLE OF CONTENTS

Page

MIII BASE STATION EMERGENCY POWER OPTIONS .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 

1

CHARGER SPECIFICATIONS  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 

2

EMERGENCY POWER OPTION SYSTEM DESCRIPTION  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 

2

CIRCUIT DESCRIPTION AND THEORY OF OPERATION
FOR THE BATTERY CHARGER  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 

2

GENERAL  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 

2

MAIN CHARGING CIRCUITRY  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 

3

OVERCURRENT PROTECTION  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 

3

INPUT OVERVOLTAGE PROTECTION  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 

3

OVERTEMPERATURE PROTECTION  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 

4

BATTERY SWITCHING OPERATION  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 

4

DEEP DISCHARGE PROTECTION  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 

4

ERROR FLAG SIGNALS  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 

4

INTERNAL BIAS VOLTAGE SOURCES  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 

4

FLOAT VOLTAGE ADJUST  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 

4

TROUBLESHOOTING PROCEDURE  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 

5

PARTS LIST

BATTERY & HARDWARE KITS  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 

5

BATTERY CHARGER  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 

8

SCHEMATIC DIAGRAM  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 

6

ASSEMBLY DIAGRAM

60 Hz CHARGER  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 

7

MASTR III STATION  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 

10

INTERCONNECTION DIAGRAM  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 

9

INSTALLATION INSTRUCTIONS  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 

13

This manual covers Ericsson and General Electric products manufactured and sold by Ericsson Inc.

NOTICE!

Repairs to this equipment should be made only by an authorized service technician or facility designated by the supplier.
Any repairs, alterations or substitution of recommended parts made by the user to this equipment not approved by the manu-
facturer could void the user’s authority to operate the equipment in addition to the manufacturer’s warranty.

NOTICE!

This manual is published by Ericsson Inc., without any warranty. Improvements and changes to this manual necessitated
by typographical errors, inaccuracies of current information, or improvements to programs and/or equipment, may be made
by Ericsson Inc., at any time and without notice. Such changes will be incorporated into new editions of this manual. No
part of this manual may be reproduced or transmitted in any form or by any means, electronic or mechanical, including
photocopying and recording, for any purpose, without the express written permission of Ericsson Inc.

The software contained in this device is copyrighted by the Ericsson Inc. Unpublished rights are reserved under the
copyright laws of the United States.

NOTICE!

LBI-38625

1

Содержание MASTR III 344A3168P1

Страница 1: ...ED IN THE OPERATING INSTRUCTIONS UNLESS YOU ARE QUALIFIED TO DO SO REFER ALL SERVICING TO QUALIFIED SERVICE PERSONNEL CAUTION WARNING TO PREVENT FIRE OR ELECTRIC SHOCK HAZARD DO NOT EX POSE THIS PRODU...

Страница 2: ...S VOLTAGE SOURCES 4 FLOAT VOLTAGE ADJUST 4 TROUBLESHOOTING PROCEDURE 5 PARTS LIST BATTERY HARDWARE KITS 5 BATTERY CHARGER 8 SCHEMATIC DIAGRAM 6 ASSEMBLY DIAGRAM 60 Hz CHARGER 7 MASTR III STATION 10 IN...

Страница 3: ...rts to the emergency power state Current instead of being sourced from the A port to the battery system is now being delivered from the battery K1 de energizes and K2 remains energized This allows up...

Страница 4: ...ed loop control group which provides the regulated output voltage to the battery Potentiometer R12 varies the amount of voltage feedback in the control loop thus allowing precise adjustment of the out...

Страница 5: ...ater than 12 25 Vdc before K2 is re en ergized to await the next emergency power state ERROR FLAG SIGNALS In the event of abnormal system operation the charger provides two error flag signals as outpu...

Страница 6: ...OT PRESENT CHECK THE FOLLOWING LINE VOLTAGE TOO LOW OPEN TRANSISTOR A1Q5 BAD I C A1U4 BAD I C A1U7 OPEN DIODE A1D9 SWITCHED GROUND NOT CONNECTED CHECK THE FOLLOWING LINE VOLTAGE TOO LOW BAD RELAY A1K3...

Страница 7: ...SCHEMATIC DIAGRAM 60 Hz CHARGER 289PS5 Rev A LBI 38625 6...

Страница 8: ...ASSEMBLY DIAGRAM 60 Hz CHARGER XP 289PS5 Rev 5 LBI 38625 7...

Страница 9: ...sistor 3 09K 1 4 W 1 Metal Film R9 M29 16001456 Resistor 274 1 4 W 1 Metal Film R10 M29 16001525 Resistor 10K 1 4 W 1 Metal Film R11 M29 16001448 Resistor 38 3K 1 4 W 1 Metal Film R12 M29 16013500 Pot...

Страница 10: ...INTERCONNECTION DIAGRAM MASTR III STATION WITH EMERGENCY POWER 19D903635 Sh 3 Rev 2 LBI 38625 9...

Страница 11: ...ASSEMBLY DIAGRAM MASTR III STATION 19D902845 Sh 10 Rev 2 LBI 38625 10...

Страница 12: ...ASSEMBLY DIAGRAM MASTR III STATION 19D902845 Sh 11 Rev 1 LBI 38625 11...

Страница 13: ...ASSEMBLY DIAGRAM MASTR III STATION 19D902845 Sh 12 Rev 1 LBI 38625 12...

Страница 14: ...BATTERY SHELF 344A4051 Sh 1 Rev 1 INSTALLATION INSTRUCTIONS LBI 38625 13...