Power Consumption
5.1
OMS 1240 Power Consumption
The maximum power consumption of the OMS 1240 is 180.5W. This value is attained
with the configuration shown in Table 5-1, with a power supply voltage of 55Vdc and
high inlet air temperature causing the fans to run at full speed.
For information on the Battery Box Unit see 03PHB00002AAR AC Power & Battery
Back-up Unit.
5.2
OMS 1260 Power Consumption
The maximum power consumption of the OMS 1260 is 348.5W. This value is attained
with the configuration shown in Table 5-1, with a power supply voltage of 55Vdc and
high inlet air temperature causing the fans to run at full speed.
Table 5-1: OMS 1200 Power Consumption
Cards/Unit configuration
OMS 1240
OMS 1260
STM-4/16 Core/CCU
25W
25W
STM-4/16 Core
22W
22W
Power LTU
0.5W
0.5W
Generic power LTU (1)
7.2W
5.3W
Generic power LTU (2)
7.2W
5.3W
Generic power LTU (3)
-
5.3W
Generic power LTU (4)
-
7.2W
Generic power LTU (5)
-
7.2W
Generic power LTU (6)
-
7.2W
Generic power LTU (7)
-
7.2W
2M core tributary (worker)
18W
-
2M core tributary (protection)
4W
-
Comms/aux/ancillary 12W
12W
Trib Card - (1)
34W
25W
Trib Card - (2)
34W
25W
Trib Card - (3)
-
25W
Trib Card (4) - Layer 2 card (1)
-
34W
Trib Card (5) - Layer 2 card (2)
-
34W
Trib Card (6) - Layer 2 card (3)
-
34W
Trib Card (7) - Layer 2 card (4)
-
34W
Fan Tray - (1)
16.5W
16.5W
Fan Tray - (2)
-
16.5W
Totals 180.5W
348.5W