Command Line Interface
Modes
Interface-ATM-VC configuration, PVC Range configuration,
VC Class configuration
Example
To configure GFR with peak cell rate to 8000 cells/sec,
minimum cell rate to 3000 cells/sec, and Maximum Burst
Size to 10 cells:
EXN400(config-vc-class)#
gfr 8000 3000 10
2.9.3.8 cdvt
Description
This command is used to configure the Cell Delay Variation
Tolerance (CDVT).
Syntax
cdvt
delay
delay
The CDVT in units of 10ns.
Default
0
Modes
Interface-ATM-VC configuration, PVC Range configuration,
VC Class configuration
Example
To configure Cell Delay Variation Tolerance to 50 ns:
EXN400(config-vc-class)# cdvt 5
2.9.3.9 mtu
Description
This command is used to configure the Maximum Transmit
Unit which represents the AAL5 frame paylod (this includes any header due
to encapsulation). The MTU size is limited by the system buffer size (for
more information see section 2.5.2 on page 12).
Syntax
mtu
mtuValue
mtuValue
The new MTU value. The lowest acceptable value
is 572. The largest acceptable value is the system
buffer size -120 bytes.
Default
1536
Example
To configure the MTU to 1500:
EXN400(config-vc-class)# mtu 1500
2.9.3.10 tx-queue-size
Description
This command is used to configure the Transmit Queue
Size. This parameter is the maximum number of buffers that can be queued
40
1553-LZY 214 2655 C 2004-11-24
Содержание EXN401
Страница 1: ...Users Guide EXN401 EXN410...
Страница 13: ...IntroductionContents Index 165 1553 LZY 214 2655 C 2004 11 24 xiii...
Страница 14: ......
Страница 95: ...Command Line Interface Default None Modes all 1553 LZY 214 2655 C 2004 11 24 81...
Страница 180: ...Ericsson AB Ericsson AB 2004 All Rights Reserved www ericsson com 1553 LZY 214 2655 C 2004 11 24...