background image

OPERATIONAL CHECKOUT

LBI-38988

Rev. B

27

2.  Place test calls from radios in Channel Test by

keying one of the  test radios and  monitoring the
audio from the other radio.  Place Clear Voice
calls and if programmed, Digital Voice calls.

Table 9 - LED Indicators for Trunked Idle Channels

LED Indicators

L1 L2 L3 L4 L5 L6 L7

Fully Trunked Idle WB
Working Channel

❍ ❍ ❍ ❍ ❍ ❍ ●

Fully Trunked Idle NB
Working Channel

❍ ❍ ● ❍ ❍ ❍ ●

Fully Trunked WB
Control Channel

❍ ❍ ❍ ❍ ❍ ●

Fully Trunked NB
Control Channel

❍ ❍ ● ❍ ❍ ●

Legend:

 = OFF

   

 = ON    

 = FLASHING

3. Verify 

LED 

indicators are correct, as shown in

Table 10, for the trunked channels assigned Clear
Voice and Digital Voice calls.

Table 10 - LED Indicators for Trunked Assigned

Channels

LED Indicators

L1 L2 L3 L4 L5 L6 L7

Fully Trunked Assigned
WB Clear Call

❍ ❍ ❍ ❍ ❍ ● ❍

Fully Trunked Assigned
WB Digital Voice Call

❍ ❍ ❍ ❍ ❍ ●

Fully Trunked Assigned
NB Clear Call

❍ ❍ ● ❍ ❍ ● ❍

Legend:

 = OFF

   

 = ON    

 = FLASHING

4. Using 

the 

System 

Manager, put channel back into

service by taking it out of Channel Test.

5.  Repeat for all channels.

Failsoft System

Perform the following steps to verify operation of a

GETC used in a Failsoft System:

1. Verify 

the  GETC LED indicators for the Failsoft

Control Channel and idle Working Channels are
correct as shown in Table 11.

Table 11 - LED Indicators for Failsoft Idle Channels

LED Indicators

L1 L2 L3 L4 L5 L6 L7

Failsoft Idle WB
Working Channel

● ❍ ❍ ❍ ❍ ❍ ●

Failsoft WB Control
Channel

● ❍ ❍ ❍ ❍ ●

Failsoft Idle NB
Working Channel

● ❍ ● ❍ ❍ ❍ ●

Failsoft NB Control
Channel

● ❍ ● ❍ ❍ ●

Legend:

 = OFF

   

 = ON    

 = FLASHING

NOTE

To switch a GETC from the Control Channel
operation to Working Channel operation, press
and hold S4 on the Control Channel GETC.  This
causes the Failsoft System to re-assign the Control
Channel  responsibilities to the next functioning
GETC.  Release S4 and verify LEDs.

2. Place Clear Voice calls on both wideband or

narrowband channels and Digital Voice calls on
the wideband channels to verify correct operation.

3. Verify 

LED 

indicators are correct, as shown in

Table 12, for the Failsoft Wideband channel(s)
assigned Clear Voice and  Digital Voice calls and
Failsoft Narrow Band channel(s) assigned Clear
Voice calls.

4.  Repeat for all channels.

NOTE

Содержание EDACS Station GETC1e 19D901868G3

Страница 1: ...LBI 38988B ericssonz ericssonz Configuration Manual EDACS Station GETC1e 19D901868G3 and G4...

Страница 2: ...is manual necessitated by typographical errors inaccuracies of current information or improvements to programs and or equipment may be made by Ericsson Inc at any time and without notice Such changes...

Страница 3: ...12 WORKING CHANNEL 12 TRUNKED FAILSOFT OPERATION 12 STATION CONTROL 13 CONFIGURATION 14 HARDWARE INSTALLATION 14 Upgrading Hardware 14 GETC Logic Board Installation 14 Turbo Board Installation 14 Rock...

Страница 4: ...IST 36 GETC CABLE 19C336863G1 36 CABLE DIAGRAMS 37 APPENDIX A A 1 APPENDIX B B 1 LIST OF FIGURES Page Figure 1 Typical EDACS Site Block Diagram 11 Figure 2 Typical Five Channel Repeater Cabinet 14 Fig...

Страница 5: ...icators in Programming Mode Using J104 23 Table 7 Sample Station Personality 24 Table 8 Channel Number Switch Settings 26 Table 9 LED Indicators for Trunked Idle Channels 27 Table 10 LED Indicators fo...

Страница 6: ...ion of the new or enhanced features and itsuse refer to Software Release Notes SRN for the specific software release For example to review release notes covering 349A9607G4 software refer to SRN1060 4...

Страница 7: ...fied site i e having the correct site color to acknowledge the receiving a radio transmission in an area where many sites may also receive the transmission This is implemented as follows 1 A particula...

Страница 8: ...rsonality space Personality programming through J104 only J100 no longer used for programming In earlier software versions the operating frequency for MII IIe systems was set into the DIP switches Wit...

Страница 9: ...7 GETC Shelf Programming Manual SOFTWARE COMPATIBILITY GETC EPROM and TURBO BOARD SOFTWARE COMPATIBILITY The following software is required for GETCs used in the Station configurations Table 1 GETC EP...

Страница 10: ...ntroller N A 344A3265G3 344A3265G6 344A3265G6 344A3265G2 VAX System Manager PDP System Manager 344A4583G2 19A149495G8 344A4583G2 19A149495G8 344A4583G2 19A149495G8 344A4583G2 19A149495G8 344A4583G2 19...

Страница 11: ...6G1 with the Speedup 80C320 microprocessor and Amps Modem chips U4 and U19 19A704727P4 Refer to Upgrading Hardware in the Hardware Installation section of this manual GETCs using EPROM 349A9607G4 or l...

Страница 12: ...with the Working Channel GETC s using a Sync line that indicates outbound Control Channel data and inbound mobile data The Sync line is connected in a bus fashion to each Station GETC CONTROL CHANNEL...

Страница 13: ...citer data line MIIe 800 900 MHz applications only SYNTH LD EN J6 15 Synthesizer exciter load enable pulse line MIIe 800 900 MHz applications only TX MOD J7 4 Direct modulation input to the synthesize...

Страница 14: ...grading to the 349A9607G4 or G5 software must ensure their hardware is upgraded to the proper level The 19D901868G4 GETC Shelf meets all Group 5 requirements Upgrading the hardware involves three elem...

Страница 15: ...4 Verify the presence of demodulated signal data at TP107 5 Adjust the transmit level potentiometer R2 for the maximum output level allowed by the phone line microwave link or equivalent communicatio...

Страница 16: ...6 1 J17 1 J18 1 J20 1 J21 1 J24 1 J25 1 J261 J48 1 J47 1 J28 1 J29 1 J44 1 J46 1 J50 1 J52 1 J53 1 J54 1 J55 1 J60 1 J61 1 J62 1 J63 1 J64 1 J66 1 J65 1 J67 1 J68 1 J69 1 1 J73 J71 1 J72 1 J74 1 J51 1...

Страница 17: ...LBI 38822 for instructions 3 Ensure Modem chips U4 and U19 are TI AMPS modems 19A704272P4 TI Amps modems are required when upgrading to 349A9607G4 or later replace if necessary 4 Ensure microprocesso...

Страница 18: ...eedy microprocessor 80C320 RYT 121 6060 A This processor is required when upgrading the software to 349A9607G4 or later The processor is available in the Speedy Upgrade Kit SPK9505 Replace if necessar...

Страница 19: ...fer to LBI 38894 for installation instructions 5 Ensure Turbo Board harness has Ferrite Toroid installed Toroid is included in the SPK9505 Speedy Upgrade Kit Replace if necessary Refer to LBI 38822 fo...

Страница 20: ...mming cable TQ 3360 between the PC and the Turbo Board programming connector When using PC Programmer TQ 3357 V3 or earlier and downloading 344A4414G3 and earlier software the data from the PC files i...

Страница 21: ...e programming the GETC Turbo Board will not alter previously stored Personality Data When Personality Data is present load1e exe clears and performs CRC functions over the code portion of memory only...

Страница 22: ...d OFF ON FLASHING 5 Proceed with the Personality programming as described in TQ 3357 Chapter 4 6 After saving the personality and downloading it into the GETC perform an operational checkout of the GE...

Страница 23: ...Proceed with the Personality programming as described in TQ 3357 5 After saving the personality and downloading it into the GETC perform an operational checkout of the GETC S4 S3 S2 S1 L1 L2 L3 L4 L5...

Страница 24: ...Mhz Ch Freq Mhz 1 855 0125 10 858 0125 19 0 0000 2 855 0250 11 858 0250 20 0 0000 3 855 0375 12 858 0375 21 0 0000 4 856 0125 13 0 0000 22 0 0000 5 856 0250 14 0 0000 23 0 0000 6 856 0375 15 0 0000 24...

Страница 25: ...36 0 54 0 GETC Personality Extended Options CV C Call Timeout 0 DV C Call Timeout 0 Wide Area DV No Data Mode RF Data Polarity Invert None Baud Rate 9600 Dig Voted Inter Unavail Data Protocol Normal...

Страница 26: ...to Table 8 7 Set S3 6 to CLOSED 8 Set S3 7 OPEN for Simulcast or CLOSED for non Simulcast With software 349A9607G4 or later set S2 6 to CLOSED use Personality Programming 9 Set S3 8 to OPEN Table 8 C...

Страница 27: ...5 Repeat for all channels Failsoft System Perform the following steps to verify operation of a GETC used in a Failsoft System 1 Verify the GETC LED indicators for the Failsoft Control Channel and idle...

Страница 28: ...D indicators when the receiver is used as a Control Channel and idle or assigned Working Channel as shown in Table 13 Table 13 LED Indicators for Satellite Site Receivers LED Indicators L1 L2 L3 L4 L5...

Страница 29: ...anager in Fully Trunked systems to display a channel failure In Trunked Failsoft the channel is removed from service to avoid using the bad channel CHANNEL ACTIVITY LOGGER Another diagnostic feature i...

Страница 30: ...uring Control Channel signaling Phone lines J6 6 7 8 9 Analog If Voter or Simulcast these lines contain modem communication between the Voter and Main Site Control Point GETCs otherwise inactive Worki...

Страница 31: ...ese lines contain modem communication between the Voter and Main Site Control Point GETCs otherwise inactive Working Channel Active During Analog Call Vol Sq J7 2 Analog Voice and Low speed data from...

Страница 32: ...hen digital call is from a console or IMC Modem data is present on the line input This looks like 2175 Secur it to the station and this line is toggled Low Delay PTT J6 1 High Transmitting Voice data...

Страница 33: ...RxD TxD BSL TxD GND GND RxD TxD GND RxD TxD GND 5 9 4 8 3 7 2 6 5 9 4 8 3 7 2 6 1 5 9 4 8 3 7 2 6 1 J101 J100 To Site Controller MSL J102 To Other GETCs BSL 5 9 4 8 3 7 2 6 1 5 9 4 8 3 7 2 6 1 J103 S...

Страница 34: ...LBI 38988B INTERCONNECT DIAGRAMS 34 Rev B MASTR III STATION INTERCONNECT...

Страница 35: ...10 OUT REM PTT IN J10 P10 13 8 V GND 1 2 1 2 P8 3 LSD IN RUS OUT TB1201 19D901868 Refer to LBI 38430 wiring diagram 19D902787 for complete wiring details MASTR IIe 19A149978 11 12 13 15 11 12 13 15 D...

Страница 36: ...A700041P32 Shell 6 Position sim to Molex 22 01 2065 P19 19A700041P32 Shell 6 Position sim to Molex 22 01 2065 MISCELLANEOUS 2 19B209727P11 Contact electrical sim to AMP 1 66504 0 3 19A704779P26 Contac...

Страница 37: ...LBI 38988 Rev B 37 GETC CABLE 19C336863G1 19C336863 Sh 1 Rev 4 19C336866 Sh 1 Rev 0...

Страница 38: ...LBI 38988B 38 Rev B This page intentionally left blank...

Страница 39: ...EDACS APPLICATIONS FREQUENCY SELECTIONS GETC DIP SWITCH SETTINGS NOTE For MASTR II IIe using Station GETC software 349A9607G4 or earlier only For MASTR II IIe and III using 349A9607G5 or later set swi...

Страница 40: ...000 851 6125 1000010 1000 851 6250 0100010 1000 851 6375 1100010 1000 851 6500 0010010 1000 851 6625 1010010 1000 851 6750 0110010 1000 851 6875 1110010 1000 851 7000 0001010 1000 851 7125 1001010 100...

Страница 41: ...1000 0001100 0100 853 1125 1001100 0100 853 1250 0101100 0100 853 1375 1101100 0100 853 1500 0011100 0100 853 1625 1011100 0100 853 1750 0111100 0100 853 1875 1111100 0100 853 2000 0000010 0100 853 2...

Страница 42: ...100 854 6125 1000100 1100 854 6250 0100100 1100 854 6375 1100100 1100 854 6500 0010100 1100 854 6625 1010100 1100 854 6750 0110100 1100 854 6875 1110100 1100 854 7000 0001100 1100 854 7125 1001100 110...

Страница 43: ...00 0010 856 1125 1001000 0010 856 1250 0101000 0010 856 1375 1101000 0010 856 1500 0011000 0010 856 1625 1011000 0010 856 1750 0111000 0010 856 1875 1111000 0010 856 2000 0000100 0010 856 2125 1000100...

Страница 44: ...010 857 6125 1000000 1010 857 6250 0100000 1010 857 6375 1100000 1010 857 6500 0010000 1010 857 6625 1010000 1010 857 6750 0110000 1010 857 6875 1110000 1010 857 7000 0001000 1010 857 7125 1001000 101...

Страница 45: ...11 1010 859 1125 1001111 1010 859 1250 0101111 1010 859 1375 1101111 1010 859 1500 0011111 1010 859 1625 1011111 1010 859 1750 0111111 1010 859 1875 1111111 1010 859 2000 0000000 0110 859 2125 1000000...

Страница 46: ...110 860 6125 1000111 0110 860 6250 0100111 0110 860 6375 1100111 0110 860 6500 0010111 0110 860 6625 1010111 0110 860 6750 0110111 0110 860 6875 1110111 0110 860 7000 0001111 0110 860 7125 1001111 011...

Страница 47: ...11 1110 862 1125 1001011 1110 862 1250 0101011 1110 862 1375 1101011 1110 862 1500 0011011 1110 862 1625 1011011 1110 862 1750 0111011 1110 862 1875 1111011 1110 862 2000 0000111 1110 862 2125 1000111...

Страница 48: ...001 863 6125 1000011 0001 863 6250 0100011 0001 863 6375 1100011 0001 863 6500 0010011 0001 863 6625 1010011 0001 863 6750 0110011 0001 863 6875 1110011 0001 863 7000 0001011 0001 863 7125 1001011 000...

Страница 49: ...01 1001 865 1125 1001101 1001 865 1250 0101101 1001 865 1375 1101101 1001 865 1500 0011101 1001 865 1625 1011101 1001 865 1750 0111101 1001 865 1875 1111101 1001 865 2000 0000011 1001 865 2125 1000011...

Страница 50: ...101 866 6125 1000101 0101 866 6250 0100101 0101 866 6375 1100101 0101 866 6500 0010101 0101 866 6625 1010101 0101 866 6750 0110101 0101 866 6875 1110101 0101 866 7000 0001101 0101 866 7125 1001101 010...

Страница 51: ...01 1101 868 1125 1001001 1101 868 1250 0101001 1101 868 1375 1101001 1101 868 1500 0011001 1101 868 1625 1011001 1101 868 1750 0111001 1101 868 1875 1111001 1101 868 2000 0000101 1101 868 2125 1000101...

Страница 52: ...10 0011 869 3625 1011010 0011 869 3750 0111010 0011 869 3875 1111010 0011 869 4000 0000110 0011 869 4125 1000110 0011 869 4250 0100110 0011 869 4375 1100110 0011 869 4500 0010110 0011 869 4625 1010110...

Страница 53: ...EDACS APPLICATIONS FREQUENCY SELECTIONS GETC DIP SWITCH SETTINGS NOTE For MASTR II IIe using Station GETC software 349A9607G4 or earlier only For MASTR II IIe and III using 349A9607G5 or later set swi...

Страница 54: ...5 1000110 0000 935 6250 0100110 0000 935 6375 1100110 0000 935 6500 0010110 0000 935 6625 1010110 0000 935 6750 0110110 0000 935 6875 1110110 0000 935 7000 0001110 0000 935 7125 1001110 0000 935 7250...

Страница 55: ...10 1000 937 1125 1001010 1000 937 1250 0101010 1000 937 1375 1101010 1000 937 1500 0011010 1000 937 1625 1011010 1000 937 1750 0111010 1000 937 1875 1111010 1000 937 2000 0000110 1000 937 2125 1000110...

Страница 56: ...100 938 6125 1000010 0100 938 6250 0100010 0100 938 6375 1100010 0100 938 6500 0010010 0100 938 6625 1010010 0100 938 6750 0110010 0100 938 6875 1110010 0100 938 7000 0001010 0100 938 7125 1001010 010...

Страница 57: ...100 939 6125 1000111 0100 939 6250 0100111 0100 939 6375 1100111 0100 939 6500 0010111 0100 939 6625 1010111 0100 939 6750 0110111 0100 939 6875 1110111 0100 939 7000 0001111 0100 939 7125 1001111 010...

Страница 58: ...LBI 38988 Ericsson Inc Private Radio Systems Mountain View Road Lynchburg Virginia 1 800 528 7711 Outside USA 804 528 7711 Printed in U S A...

Отзывы: