Ergotron StyleView SV32 Скачать руководство пользователя страница 2

2 of 10

888-83-065-G-01 rev. E 

• 03/19 

Maintenance & Safety

 

Color

Symbol

 

Signal 

Word

Level of Hazard

Red

DANGER

Indicates an imminently hazardous situation which, if not 
avoided, will result in death or serious injury.

Orange

WARNING

Indicates a potentially hazardous situation which, if not 
avoided, could result in death or serious injury.

Yellow

CAUTION

Indicates a potentially hazardous situation which, if not 
avoided, may result in minor or moderate injury.

None

CAUTION

Used without the safety alert symbol indicates a poten-
tially hazardous situation which, if not avoided, may 
result in property damage.

Red,

Orange

or 

Yellow

Electrical

Indicates an impending electrical hazard which, if not 
avoided, may result in personal injury, fi re and/or death.

Hazard Symbols Review 

The Meaning of Symbols appearing in this Guide, on the Cart or on the Power System
These symbols alert you to a safety condition that demands your attention. You should be able to recognize and understand the signifi cance of the following Safety Hazards if 
you encounter them on the Cart or within Cart documentation such as this Set-up Guide.

33 Amp-Hour Batteries

BATTERY 

LEAD

  WARNING: 

 RISK OF ELECTRICAL DISCHARGE

• Do NOT swap battery cables, doing so will cause arcing and trip the circuit breaker.
• Do not remove or replace the batteries while cart is located in an oxygen rich or hazardous environment, arcing may occur and cause combustion.
• Replace fi rst battery before removing second battery to reduce the risk of cables touching terminals and causing arcing.

• Always replace both batteries!
• Replace fi rst battery before removing second battery.
• Replace batteries with same Amp/Hour rating batteries only.
• Only Ergotron-specifi ed batteries may be used in the StyleView Power System. Please call customer care for more details.
• Recycle battery or contact Ergotron for proper battery disposal guidelines.

20 Amp-hour Batteries

BATTERY REPLACEMENT

The power module is configured for two, 33 -Ah batteries. 
Only the following batteries are compatible with this 
system:

•  B&B EP33-12 

•  SBS S-12330

•  Longway 6FM33G 

•  Vision 6FM33D

•  Vision 6FM33HD-X 

•  PBQ PBQ33-12L

•  Werker WKA12-33C  

•  Werker WKA12-35C

•  Duracell Dura 12-35C

Installing batteries other than the 33 -Ah listed above will 
void the product warranty. Failure to heed this warning 
may result in severe damage to batteries, power module 
and possible fire hazard.

REMPLACEMENT DE LA BATTERIE

Le module d’alimentation est configuré pour deux batteries 33 A-h. 
Seules les batteries suivantes sont compatibles avec ce système :

•  B&B EP33-12 

•  SBS S-12330

•  Longway 6FM33G 

•  Vision 6FM33D

•  Vision 6FM33HD-X 

•  PBQ PBQ33-12L

•  Werker WKA12-33C  

•  Werker WKA12-35C

•  Duracell Dura 12-35C

L’installation de batteries autres que les batteries 33 A-h citées 
ci-dessus annulera la garantie du produit. Si vous ne vous conformez 
pas à cette précaution d’utilisation, les batteries et le module 
d’alimentation risquent d’être sérieusement endommagés, ce qui 
pourrait provoquer un incendie. 

WARNING

AVERTISSEMENT

822-386

www.ergotron.com

Содержание StyleView SV32

Страница 1: ...ano Svenska 日本語 汉语 10 C 50 F 29 C 86 F Relative Humidity Range 5 95 rH Operational 20 C 4 F 50 C 122 F Relative Humidity Range 5 95 rH Storage BATTERY LEAD Please dispose of all batteries in accordance with local law Two Sealed Lead Acid Absorbed Glass Mat 12VDC batteries Depends on battery StyleView SLA Change Power System Batteries SV32 S SV32 T SV32 SV32 PHD SV42 English For the latest User Ins...

Страница 2: ...ch or hazardous environment arcing may occur and cause combustion Replace first battery before removing second battery to reduce the risk of cables touching terminals and causing arcing Always replace both batteries Replace first battery before removing second battery Replace batteries with same Amp Hour rating batteries only Only Ergotron specified batteries may be used in the StyleView Power Sys...

Страница 3: ...SV32 S SV32 T SV32 Turn off all mounted equipment Disconnect Power System from power source Turn power system off by holding down the AC Outlet Power button for 1 3 seconds Power light will shut off If your cart has circuit breakers switch them both to OFF ...

Страница 4: ...posal guidelines Caution Replace only one battery at a time Do NOT swap battery cables doing so will cause sparking and trip the circuit breakers Depends on battery Black Caution Connect Red before connecting Black Caution Remove Black before removing Red Red Red Black BATTERY LEAD Recycle battery or contact Ergotron for proper battery disposal guidelines Red Caution Connect Red before connecting ...

Страница 5: ...ystem by holding power buttondown for 1 3 seconds With cart s power cord plugged into the wall outlet wait until cart is at 100 charge takes aproximately up to 7 hours to charge Plug Cart s Power Cord into wall outlet Do Not stretch coiled cord further than 8 feet 2 5 meters damage to the cord may occur CAUTION There is no on off switch on this equipment the AC power cord is the only power disconn...

Страница 6: ...er button for 1 3 seconds Power light will shut off BATTERY LEAD Recycle battery or contact Ergotron for proper battery disposal guidelines Caution Replace only one battery at a time Do NOT swap battery cables doing so will cause sparking and trip the circuit breakers Turn both circuit breakers to OFF Red Black Caution Remove Black before removing Red Red Caution Connect Red before connecting Blac...

Страница 7: ...ely up to 7 hours to charge Plug Cart s Power Cord into wall outlet Do Not stretch coiled cord further than 8 feet 2 5 meters damage to the cord may occur CAUTION There is no on off switch on this equipment the AC power cord is the only power disconnect The socket outlet should be easily accessible and should be installed near the equipment Note If StyleLink is installed it will report battery sta...

Страница 8: ...ower button for 1 3 seconds Power light will shut off Turn both circuit breakers to OFF Red Red Black Black BATTERY LEAD Caution Remove Black before removing Red Recycle battery or contact Ergotron for proper battery disposal guidelines Caution Replace only one battery at a time Do NOT swap battery cables doing so will cause sparking and trip the circuit breakers Caution Connect Red before connect...

Страница 9: ...AD Caution Remove Black before removing Red Recycle battery or contact Ergotron for proper battery disposal guidelines Caution Replace only one battery at a time Do NOT swap battery cables doing so will cause sparking and trip the circuit breakers Caution Connect Red before connecting Black ...

Страница 10: ...tch coiled cord further than 8 feet 2 5 meters damage to the cord may occur CAUTION There is no on off switch on this equipment the AC power cord is the only power disconnect The socket outlet should be easily accessible and should be installed near the equipment Note If StyleLink is installed it will report battery status checking until battery has gone through one full cycle charge to 100 discha...