Operating instruction
Hydraulic system with Motor drive PXD compact
Document no.: B-00021
Edition 2019 09
Operating instruction EN
Copyright by Ergoswiss AG
23/25
8.5
Error messages on the display
(Only with manual control switch type Memory!)
Display
Cause
Rectification
The control box compact is equipped
with an overheating protec-tion. This
overheating protection will activate
due to too high temperatures
Wait until the control box has cooled down and the
message
«HOT»
is no longer displayed. Then the
control box is ready for operation again.
There is an internal error at the control
box.
Proceed according to the following error list.
00
Internal error channel 1
Disconnect the power cable from the mains and
contact the customer service.
01
Internal error channel 2
12
Defective channel 1
Insert the motor cable correctly.
13
Defective channel 2
24
Excess current motor M1
System overloaded
→
Remove load from the sys-
tem
System jammed
→
remove clamped object
25
Excess current motor M2
48
Excess current motor group 1
49
Excess current motor group 2
60
Collision protection
62
Excess current at the control
36
Plug detection at motor socket M1
Plug in the motor cable correctly at the respective
socket.
Perform a reset.
37
Plug detection at motor socket M2
61
Motor replaced
55
Synchronising of the motor group 1
impossible
Remove load from the system. Perform a reset.
Contact the customer service if the error remains
displayed.
56
Synchronising of the motor group 2
impossible
67
Too high voltage
Disconnect the power cable from the mains.
Contact the customer service.
70
Change of the drive configuration
Disconnect the power cable from the mains and
wait at least for 5 seconds. Reconnect the power
cable and perform a reset.
81
Internal error
Disconnect the power cable from the mains and
wait at least for 5 seconds. Reconnect the power
cable and perform a reset.
Contact the customer service if the error remains
displayed.
93
Connection error while synchronising
The error is displayed for 15 seconds,
then the control box changes to the
reset mode with a flashing display of
«000»
.
Disconnect the power cable from the mains and
wait at least for 5 seconds. Reconnect the power
cable and perform a reset.