Super Shot 125 DC 70CFM EU Part Manual
Chapter 8 Troubleshooting
©2022 by Crafco, Inc. All Rights Reserved
………………………………………………………...Troubleshooting (48300N) 8-30
Step
Possible Cause
If . . .
3b
Is there 12 Vdc between the trigger
“RED”
wire (the second red trigger wire) going
toward the hose and a nearby ground
source?
(Make sure the wand trigger is pulled during this
Step.)
• Yes, go to Step 3c.
• No, go to Step 4.
3c
Is there 12 Vdc between the trigger
“GRN/WHT-CH1-M” wire coming from the
control box and a nearby ground source?
(Make sure the wand trigger is pulled during this
Step.)
• Yes, go to Step 5.
• No, check for a broken wire or poor wire
crimp on the
“GRN/WHT-CH1-M” wire
going to the control box.
4
Disconnected the five-pin connector between the
hose and wand. Refer to
Is there continuity on the wand connector
between red trigger "C" post and red trigger "B"
post while the wand trigger is pulled?
• Yes, go to Step 4a.
• No, call Crafco, Inc. and request an
RA # so you can send your wand
back for repair.
4a
Disconnect the two red trigger wires in the
junction box going toward the hose. Move the
wand end of the hose next to the junction box.
Is there continuity on the hose connector "C"
socket and only one red trigger in the junction
box?
(Check both red trigger wires in the junction box
one at a time.)
• Yes, go to Step 4b.
• No, recheck the hose connector "C"
socket to the other red trigger wire in
the junction box. (You want to see
continuity between only one red trigger
wire and the "C" socket.)
• Still no or continuity to both red trigger
wire, then call Crafco, Inc. and request
an RA# so you can send your hose
back for repair.
4b
Is there continuity on the hose connector "B"
socket and red trigger in the junction box?
• Yes, call Crafco, Inc. and speak to a
service technician, you should have
found the problem.
• No, recheck the hose connector "B"
socket to the other red trigger wire in
the junction box. (You want to see
continuity between only one red trigger
wire and the "B" socket.)
• Still no or continuity to both red trigger
wire, then call Crafco, Inc. and request
an RA# so you can send your hose
back for repair.
Table 8-24 Pump Electrical Troubleshooting (continued)
Содержание Crafco SUPER SHOT 125
Страница 1: ...Parts Manual 26635N Revision E SUPER SHOT 125 DIESEL COMPRESSOR 70CFM EU MELTER...
Страница 4: ...Super Shot 125 Diesel Compressor 70 CFM EU Melter PN 48300N...
Страница 5: ......
Страница 16: ......
Страница 26: ......
Страница 42: ......
Страница 72: ......
Страница 76: ......
Страница 120: ......
Страница 170: ......
Страница 174: ......
Страница 175: ......
Страница 176: ...2022 Crafco Inc...