EG_GenPro25e_1055_UG_002_UK
Page 24 / 58
Descriptions and non-contractual illustrations in this document are given as an indication only.
ERCOGENER reserves the right to make any modification.
Dct_427_02
3.4.2.2
Consumption of the GenPro 25e
Table 7 : Power supply range
Standard
+6,5V
DC
à +32V
DC
With battery option (S0431B)
+7,2V
DC
à +32V
DC
3.4.2.2.1 Consumption in standard mode
Table 8 : Consumption in Low Power mode @ 25 °C without battery charging
This Low Power mode is available only with
EasePro > V2.20
Low Power mode
Average I nominal
.
Unit.
V
IN
6.5
12
24
32
V
GSM / GPRS
3
2
1
1
mA
The GenPro 25e is in Low Power mode with the command
AT+EGLOP=1,xx
.
The GenPro 25e is attached to the network.
Table 9 : Consumption in attached mode @ 25 °C without battery charging
Mode attaché
I
MOY MAX.
Unit.
V
IN
6.5
12
24
32
V
GSM / GPRS
56
32
18
16
mA
The GenPro 25e is attached to the network.
Table 10 : Consumption in data transfer @ 25 °C without battery charging
Unit
V
IN
6.5
12
24
32
V
GSM
900
(1)
I
MOY MAX
260
130
60
50
mA
I
Peak MAX
1380
650
320
250
mA
1 800
(2)
I
MOY MAX
230
140
100
90
mA
I
Peak MAX
750
400
230
190
mA
GPRS
1 Rx / 1 Tx
900
(1)
I
MOY MAX
250
120
60
50
mA
I
Peak MAX
1360
650
320
250
mA
1 800
(2)
I
MOY MAX
210
140
90
90
mA
I
Peak MAX
730
390
230
190
mA
3 Rx / 2 Tx
900
(1)
I
MOY MAX
360
180
90
70
mA
I
Peak MAX
1130
550
280
210
mA
1 800
(2)
I
MOY MAX
280
170
110
100
mA
I
Peak MAX
640
360
210
180
mA
(1)
adapted antenna, RF power max. 33dBm.
(2)
adapted antenna, RF power max. 30dBm.