3.10 Power supply output V
BAT
Table 27 : Description of the power supply
V
BAT
Signal
14-pin connector
Pins N°
I/O
Kind of I/O
Description
+4.8V
GND
7
O Analog
Output voltage
3.55 V
DC
≤
V
BAT
≤
4.5 V
DC
.
8
Corresponds to wires
Orange for +
V
BAT
Black for
GND
see ANNEX 2 - 14-pins Micro-FIT cable (Inputs/Outputs)
Table 28 : Conditions of use of the power supply output V
BAT
Parameters
Condition
Min.
Typ.
Max.
Unit
V
OUT
Without power supply
1
3.55
4.0
V
DC
With power supply 8V - 32V
4.2
4.4
V
DC
I
OUT
Max.
100
2
mA
DC
1
The GenLoc 54e works with its battery only. In the case where the voltage V
BAT
falls below 3.55 V
DC
, the
product cannot communicate anymore via the network.
2
In the case where the software management of the battery guarantees that the voltage V
BAT
does not fall
below 3.55 V
DC
. In case of low battery (V
BAT
< 3.55 V
DC
) or high discharge (V
BAT
= 2.8 V
DC
), and in order to
guarantee a restart of the product, the consumption on this output must not exceed 50 mA.
2.8 V
DC
is the self-protection limit of the battery. From this moment, the battery puts itself
under protection, and the output voltage becomes null.
When the battery is not connected, the output voltage is 4.2 V
DC
≤
V
OUT
≤
4.4 V
DC
as long as
the power V
DC
is present.