EG_GenTrack23e_997_UG_005_UK
Page 25 / 39
Descriptions and non-contractual illustrations in this document are given as an indication only.
ERCO&GENER reserves the right to make any modifications.
5.1.5 Checking the USB communication with the GenTrack 23e
5.1.5.1 With the configuration tool "GenTrack Config"
Please, refer to the User Guide of the configuration tool "
GenTrack Config"
:
EG_GenTrack Config_UG_xxx_yy.pdf
5.1.5.2 With a software Terminal like Hyper Terminal®
Connect the USB link between the terminal (DTE) and the charger support of the GenTrack 23e (DCE).
Configure the COM port of the DTE as follows:
▪
Bits per second :
115200 bps,
▪
Data Bits
:
8 bits,
▪
Parity
:
without parity,
▪
Stop Bits
:
1,
▪
Flow control
:
None.
Use a communication software like Windows HyperTerminal®.
- Put the unit on the charger and wait for the initialization time of the CPU processor (less than 8 seconds).
Two possible displays are possible:
A – If the unit already contains an application:
The unit returns the following signature: (example of display):
*********************************************************
EaseTrack-01 V1.10, Date: Thu Jan 28 14:19:53 2010: initType = 0x0000
*** BALISE READY - active = 0, func = 2 ***
To read again the version of the embedded application:
When the GenTrack 23e replies to the activated version, we can consider that the communication with the
GenTrack 23e has been correctly established.
Command
Response
Interpretation
ATi8
API: EaseTrack-01 V1.10, Date: Thu Jan 28 14:19:53 2010
OK
The activated and
loaded version is
V1.10