English

 Read the instructions carefully  

 

    before installation and commis- 

     sioning! 

 Leave the instructions for users/ 

 

    customers for future reference! 

 Our updated product documen- 

 

    tation can be accessed at  

     www.erco.com/download.

Required mounting accessories

Mount only in recessed housing 33295 

or use mounting kit 33293.

Recessed housing

for mounting luminaires flush or to 

cover the edge.

Mounting kit

for mounting luminaires in hollow 

floors to cover the edge.

General safety information

 

 Warning! 

   

Risk of electric shock! 

 

- Before carrying out maintenance and 

installation on the luminaire, discon-

nect from the mains supply and also 

from any other DALI control wiring, and 

ensure that all power is switched off.

- Never operate luminaires with damaged 

connection cables or damaged or miss-

ing protective shield.

Attention!

- Do not open the luminaire. In case of 

damage or a defective LED module, the 

entire luminaire must be returned to 

the factory. 

- When installing, always observe the 

national installation and accident pre-

vention regulations.

Intended use

- The luminaire is dust- and pressure-

water tight. It is protected against the 

consequences of continuous submer-

sion up to a maximum depth of 3m 

(IP68 3m). 

- The luminaire is suitable for both out-

door and indoor use.

- When mounting in hollow or raised-

floor structures, please note than only 

luminaires with overlap trim can be used.

- Luminaires mounted in recessed hous-

ing can be walked on. The recessed 

housing can be driven over by vehicles 

with pneumatic tyres provided it is  

screwed to a suitable base.

Restrictions 

- The maximum load of 20kN of the lu-

minaire and the accessories depends on 

the load bearing capacity of the ground 

and must not be exceeded. 

- Luminaires mounted in recessed housing 

can be driven over by vehicles provided 

the housing is screwed to a suitable base.

 

Choosing the mounting location

- Position the luminaire so as to avoid 

operation in direct sunlight or near other 

sources of heat. High ambient tempera-

tures can reduce the life and efficiency 

of the control gear or LED module.

- The luminaire may be mounted in hol-

low floors such as catwalks or wooden 

terraces using the mounting kit. 

- The luminaire may be mounted with 

some restrictions in the area of road-

ways using the recessed housing.

 

 

Caution! 

     

Risk of accident!

When mounted on traffic routes, please 

note that the glass poses an increased 

risk of slipping or skidding when wet. 

Safety glass

 

 Warning! 

   

Risk of electric shock! 

 

The safety glass functions as a protec-

tive shield. The luminaire must only be 

used complete with its protective shield.

Y

 A damaged protective shield must 

be replaced.

Return the entire luminaire to the factory.

Load on the safety glass

Avoid loads involving hard objects, im-

pact or blows.

Surface temperature of the safety glass

In an ambient temperature of 25°C the

safety glass may reach a maximum sur-

face temperature of 52°C.

Electrical installation

For 3-circuit installation: to avoid any 

damage to the control gear, the neutral 

conductor must never be connected or 

disconnected during operation.

Overvoltage protection

ERCO uses electronic control gear with 

overvoltage protection in accordance 

with DIN EN 61547. If additional protec-

tion from spikes is required, e.g. when 

switching off inductive loads, separate  

overvoltage protection units should be 

installed.

Luminaire with DALI control gear

- All cables, materials and devices used 

must be suitable for mains voltage, as 

the DALI signal is not transmitted using 

safety extra low voltage (SELV).

- For general information on DALI, please  

go to:  

www.digitalilluminationinterface.org.

Mounting

1. Mount the accessories in accordance 

with the accessory instructions. 

2. Make the electrical connection via a 

terminal (to be provided on-site) and 

junction box (to be provided on-site) 

(Fig. 1). 

Requirements for the connection  

terminals

- 2-pole screw terminal or screwless 

terminal (standard), 

4-pole screw terminal or screwless  

erminal (DALI)

- 250V min.

- 1A min.

- Prepare conductor ends as specified 

by the terminal manufacturer.

- Always fit the terminal in a suitable 

junction box or branch sleeve in compli-

ance with the national regulations.

Wiring connections for DALI

Brown  

Phase

Blue     

Neutral conductor

Black    

DALI

Grey    

DALI

3. Place the luminaire in the frame and 

ensure correct orientation towards the 

wall (Fig. 2).

Adjusting the luminaire (Fig. 3)

For optimum grazing light wallwashing 

the luminaire can be adjusted by +/-10°. 

1. To do so, slot the supplied mounting 

tool at the narrow, right side of the lu-

minaire between the mounting frame 

and the luminaire.

2. Tilt the LED module into the required 

position. 

Removing the luminaire (Fig. 4)

1. Slot the two supplied mounting tools at 

the narrow sides of the luminaire between 

the mounting frame and the luminaire. 

The nib of each mounting tool must 

face towards the luminaire. 

2. Lift the luminaire out of the frame 

using both mounting tools at the same 

time.

Dimming

Depending on the version, the luminaire 

can be dimmed via suitable dimmers 

(trailing edge).

Trailing edge dimmers

Follow the manufacturer’s installation 

instructions.

For some products, the luminaire can 

only be switched on in the upper dim-

ming range. Before installation and con-

nection, check luminaire, control gear 

and dimmer combination for proper 

functioning of the dimmer, especially 

when using universal dimmers. 

The use of dimmers which are unsuit able 

for LED drivers can damage the lumi-

naire, control gear and/or the dimmer.

No responsibility is accepted for the 

use of dimmers that are unsuitable for 

the luminaire.

Operating instructions

Repairing the connection cable

The connection cable may be trimmed if 

damaged. To replace the connection ca-

ble, return the entire luminaire to the 

factory.

Please note: The connection cable has 

capillary protectiona and is watertight 

length-wise and may only be replaced 

by the manufacturer.

Flashing of the LED module 

It is normal for the LED module to  

flicker when switching on and off.

Cleaning

Always clean carefully using a soft cloth 

and a commercially available, ph-neutral,  

alcohol-free, non-abrasive cleaning 

agent.

Cleaning the safety glass

Safety glass can be cleaned with clean-

ing agents that are also suitable for 

glass-ceramic cooking hobs.

Disposal

 In accordance with EU Directive 

 

WEEE (Waste Electrical and 

Electronic Equipment), luminaires must 

not be disposed of with other household 

waste. At the end of their life, luminaires 

must be taken to the appropriate local  

facility available for the disposal or recyc-

ling of electronic products.