3000054936
0819
E
ERCO GmbH
Postfach 24 60
58505 Lüdenscheid
Brockhauser Weg 80-82
58507 Lüdenscheid
Germany
Tel.: +49 2351 551 0
Fax: +49 2351 551 300
[email protected]
www.erco.com
Notes and safety instructions
Luminaires for ERCO track
English
Follow the luminaire installation
instructions.
Read the instructions carefully
before installation and commis-
sioning!
Leave the instructions for users/
customers for future reference!
Our updated product documen-
tation can be accessed at
www.erco.com/download.
General safety information
Warning!
Risk of electric shock!
- Before carrying out maintenance and
installation on the luminaire, discon-
nect from the mains supply and also
from any other DALI control wiring, and
ensure that all power is switched off.
- Never operate luminaires with damaged
connection cables. The connection cable
may only be replaced by the manufac-
turer.
Caution!
Blue light hazard!
RG2
Position the luminaire
marked with one of two
adjacent pictograms so
that extended gazing into the luminaire
from a distance of less than xm is not
expected. Find the value for x in the
included graphic installation instructions.
Caution!
Risk of fire!
This sign
w
on the luminaire symbo-
li ses the safety distance between lumi-
naire and directly illuminated object
in beam direction. Failure to keep this
safety distance may damage the object
or cause fire.
Caution!
Risk of burns!
Luminaire with this pictogram
in the attached graphic moun-
ting instructions may reach sur-
face temperatures of more than 60° and
cause skin burns. This luminaire must be
installed outside of the hand area.
Attention!
- In case of damage or a defective LED
module, the entire luminaire must be
returned to the factory.
- When installing, always observe the
national installation and accident pre-
vention regulations.
Intended use
The luminaire is suitable for use
in dry interiors only.
- The luminaire is only approved for
mounting in ERCO 220-240V track.
- If ERCO adapters are used with pro-
ducts manufactured by third parties,
no liability can be accepted for the elec-
trical safety and functionality of the
combined system or for consequential
damage resulting from the combina-
tion. The liability for defective ERCO
adapters remains unaffected.
Restrictions
Luminaires with transadapters or DALI
transadapters may not be installed in
singlets.
Wall-mounting
If track is mounted horizontally, only
luminaires weighing up to a maximum
of 2kg may be used.
If vertically mounted, the guiding
groove on the track profile must be
facing to the right. Only use luminaires
weighing up to a maximum of 3.5kg.
Choosing the mounting location
Position the luminaire so as to avoid
operation in direct sunlight or near
other sources of heat. High ambient
temperatures can reduce the life and
efficiency of the control gear or LED
module.
Operating DALI luminaires
RGBW luminaires
By combining red, green and blue colour
mixing with warm white LEDs at different
dimming levels, all colours, shades and
colour temperatures can be created. To
control the colours via a DALI system with
colour management, the signal input has
a DALI interface with an address for the
luminaire. When operated using a system
without colour management, 3 addresses
per luminaire are used.
The colour compensation guarantees
that exactly the same colour of light is
obtained from all controlled luminaires
which have the same DALI control set-
tings.
Parscan
∅
188mm
To control the luminaire, the 2 addresses
must be grouped.
DALI standard
For general information on DALI, please
go to:
www.digitalilluminationinterface.org.
Luminaires with Casambi Bluetooth
control
- For control of the luminaire you need
a Bluetooth 4.0-capable smartphone or
tablet and the Casambi app for iOS or
Android downloadable for free in the
specific app stores.
- You can couple up to 127 luminaires in a
Casambi mesh network. This number can
be increased via several parallel networks.
- Because the switching signal in a mesh
network is transferred from luminaire
to luminaire, the spacing between two
luminaires must not exceed 10m. This
distance may be less according to the
environment. For this reason you should
check possible spacing between the
lumi naires prior to installation.
- ERCO GmbH hereby declares that the
track luminaires with Casambi control
are compliant to Directive 2014/53/EU.
Radio operation is implemented on
frequency bands 2402 – 2480MHz with
maximum transmission power of 4dBm.
The complete text of the EU declaration
of conformity is available at the following
internet address:
www.erco.com/casambi-ce.
Electrical installation
For 3-circuit installation: to avoid any
damage to the control gear, the neutral
conductor must never be connected or
disconnected during operation.
Overvoltage protection
ERCO uses electronic control gear with
overvoltage protection in accordance
with DIN EN 61547. If additional protec-
tion from spikes is required, e.g. when
switching off inductive loads, separate
overvoltage protection units should be
installed.
Dimming
Depending on the version, the luminaire
can be dimmed via suitable dimmers
(trailing edge).
Trailing edge dimmers
Follow the manufacturer’s installation
instructions.
For some products, the luminaire can
only be switched on in the upper dim-
ming range. Before installation and
connection, check luminaire, control
gear and dimmer combination for proper
functioning of the dimmer, especially
when using universal dimmers.
The use of dimmers which are unsuitable
for LED drivers can damage the lumi-
naire, control gear and/or the dimmer.
No responsibility is accepted for the use
of dimmers that are unsuitable for the
luminaire.
On-board Dim (potentiometer)
The luminous flux can be continuously
dimmed with the rotary control on the
luminaire, also in addition to the dim-
mer with trailing edge technology.
Rotating the light distribution
- When using floodlights with oval
flood characteristic, the orientation of
the beam can be rotated.
When undoing the lens mount, ensure
that the Spherolit lens does not fall out.
- When using wallwashers, ensure cor-
rect rotation of the Spherolit lens wall-
wash, as otherwise this will alter the
light distribution.
Flashing of the LED module
It is normal for the LED module to
flicker when switching on and off.
Cleaning
Always clean carefully using a soft
cloth and a commercially available,
ph-neutral, alcohol-free, non-abrasive
cleaning agent.
Disposal
In accordance with EU Directive
WEEE (Waste Electrical and Elec-
tronic Equipment), luminaires must not
be disposed of with other household
waste. At the end of their life, lumi-
naires must be taken to the appropriate
local facility available for the disposal
or recycling of electronic products.