18
Operators Manual ES-640PIA
Troubleshooting
If the engine does not start:
• Ignition interruption switch to position “ON”?
• Spark plug connector plugged in?
• The safety switch on the fan interrupts the ignition
current?
• Replace defective switches if necessary. Tighten the
butterfly screw and/or the wing nuts so that the mount
-
ing collar of the suction trunk holds the switch pressed.
•
Fuel tank filled with petrol?
• Fuel tap at position ON?
Warning:
Waste that has clogged the unit may contain
sharp-edged glass or ceramic fragments and
metal parts. There may be sharp edges in
the unit.
Always wear protective gloves when working
on the turbine and removing blockages.
Risk of injury due to sharp edges.
DANGER:
Before carrying out any work on the unit, re-
move the ignition interruption switch to position
„Off“ and remove the spark plug connector.
Risk of serious injuries.
Heavy-duty zipper:
•
Zipper stiff?
Clean the zipper with a strong brush and soap suds,
dry and treat with talcum.
Maintain the zipper regularly with talcum.
In case of insufficient suction power:
• Collecting bag full?
• Collecting bag dirty or clogged?
Clean or wash the collecting bag regularly.
• Suction trunk or suction hose blocked?
•
Switch off the engine and wait for the engine to stop.
Only then remove suction trunk and remove material.
Wear protective gloves.
• Fan blocked, impeller blocked.
Switch off the engine and wait for the engine to stop.
Only then remove suction trunk and remove material.
For better accessibility, the turbine cover can also be
removed. Wear protective gloves.