EG_GenPro78e_1003_UG_007_UK
Page 30 / 41
Description and non-contractual illustrations in this document are given as an indication only.
ERCO & GENER reserves the right to make any modifications.
7.3.2 Auto-baud mode
The auto-baud mode allows the modem to automatically detect the transmission speed used by the DTE.
(only from 1200 up to 115200 bps).
The auto-baud mode is controlled by the command
AT+IPR
. This function is explained in detail in the ERCO
& GENER “Commands List”.
Note: By default, the
GenPro 18e
is delivered with the RS232 interface configured to 9600 bps, no parity, 8
data bits, 1 stop bit.
It is recommended to prefer a fixed speed to the auto-baud mode.
7.3.3 Auto-power supply mode through the pin RI
An option (not soldered by default) exists allowing the auto-power supply mode in 3.8V, through the pin RI ,
for an external application (the GenBlue 15e for instance).
7.3.4 Pins description
Table: Pins description
Signal
Pin number on Sub
HD connector
I/O
RS232
standard
Description
CTXD/CT103
2
I
TX
Transmit serial data
CRXD/CT104 16 O
RX
Receive
serial
data
CRTS/CT105
12
I
RTS
Request To Send
CCTS/CT106
11
O
CTS
Clear To Send
CDSR/CT107 7 O
DSR
Data
Set
Ready
CDTR/CT108-2
8
I
DTR
Data Terminal Ready
CDCD/CT109
1
O
DCD
Data Carrier Detect
CRI/CT125
13
O
RI
Ring Indicator / 3.8V option (*)
CT102/GND 9
Ground
(*) This 3.8V auto-power supply option is not wired by default.