SAFETY INSTRUCTIONS

Please note: Before assembling and putting the pump into operation, in all cases read 
through the operating manual. For safety reasons, those persons who have not read 
through the operating manual may not use the pump. The pump is intended for use 
ONLY by adults who have fully read and understand these instructions. Whenever  
Water and Electric are in the same place there are risks of electrocution and serious 
injury or death. Always disconnect the pump RCCB from the mains before placing your 
hand in the water to service maintain or clean the pump. The pump is ONLY intended 
for use with water or water based (aqueous solutions) which have a content of at least 
90% water. DO NOT use this pump for flammable, toxic, corrosive or irritant fluids.
a)  The user is responsible towards third parties with regard to the use of the pump  
 

(water installations, etc.)

b)  Only operate on connections with residual current circuit breakers! Your   
 

pump is fitted with an RCCB as standard. If removed for pump installation, it  

 

must be replaced before the pump is switched on.

c) 

Before putting into operation, a qualified electrician must check that the required  

 

electrical safety measures are place.

d)  The electrical connection is to be made via an electrical socket.
e)  Check the voltage. The specified technical information on the label must 
 

correspond to the voltage of the electrical equipment.

f) 

During the operation of the pump, persons may not remain in the pumped  

 medium.
g)  The temperature of the fluid to be pumped may not exceed 35°C. In the event that 
 

extension cables are used, they must be exclusively made out of rubber, type H07 

 

RN-F, and in compliance with norm DIN 57282 or DIN 57245. Never handle, lift or 

 

carry the pump connected to electrical power by the cord. Make sure that the 

 

connection power outlet is kept away from water and moisture and that the 

 

power plug is protected from moisture.

h)  Before putting the pump into operation, check that the electrical cord and 
 

electrical residual current circuit breaker are not damaged.

i) 

Always pull out the residual current circuit breaker from the electrical  socket  

 

before performing work on the pump.

j) 

In the event that the pump is to be installed in a storm drain, one must 

 

subsequently close the storm drain with a cover in order to safeguard the safety 

 of 

pedestrians.

k) 

Reinforce the mounting of the discharge pipe with the use of a pipe clip. Adhere 

 

to the maximum immersion depth (See: Technical Information). The owner 

 

(user)of the pump has the duty to take precautionary measures (installation of an 

 

alarm device, back-up pump, etc.) for the avoidance and prevention of potential 

 

damages (such as flooded rooms, etc.) due to faulty pump operation (because of 

 

breakdowns or defects).On sandy or silty ground it is necessary to let the pump  

 

run hanging by a rope or chain or to situate the pump on a suitable base in order  

 

to prevent the sinking of the intake section.

Содержание ERB400SWP

Страница 1: ...ERB400SWP 400W AUTOMATIC STAINLESS STEEL SUBMERSIBLE CLEAN WATER PUMP...

Страница 2: ...400W AUTOMATIC STAINLESS STEEL SUBMERSIBLE CLEAN WATER PUMP 2...

Страница 3: ...e contact Screwfix Direct Ltd on Freephone 0500 41 41 41 If the fault occurs within the first 12 months you may return the goods for a full refund or we will repair or replace the goods if you prefer...

Страница 4: ...abel must correspond to the voltage of the electrical equipment f During the operation of the pump persons may not remain in the pumped medium g The temperature of the fluid to be pumped may not excee...

Страница 5: ...t be replaced In the event of damage to the cable the device should be scrapped o Note this product has internal lubricant which may escape contaminating the water consequently the pump is not suitabl...

Страница 6: ...ot use this instrument when there is a fault in the above mentioned process test Test before use it SYMBOLS Read the user manual Denotes risk of personal injury loss of life or damage to the tool in c...

Страница 7: ...7 400W AUTOMATIC STAINLESS STEEL SUBMERSIBLE CLEAN WATER PUMP 3 1 5 6 4 2 1 ELECTRICAL CABLE 2 HANDLE 3 BRACKET FOR FLOAT SWITCH 4 UNIVERSAL CONNECTING PIECE 5 FLOAT SWITCH 6 INTAKE PORT...

Страница 8: ...HNICAL INFORMATION Nominalpower 400W Ratedvoltage frequency 240V 50Hz Max pumpingheight 7m Max flowrate 8 000l h Max particlesize 5mm Max immersiondepth 6m Max pumpingpressure 0 8bar Cable10mH05RN F3G...

Страница 9: ...e pumping height and flow rate Use only flat hoses The on and off switching levels can vary The specified values are average values and do not apply if the float switch is not affixed to the bracket f...

Страница 10: ...he pump easier it is recommended to let the air escape by submerging the pump with the outlet connections directed upwards Note Please put the pump into the water at an angle so that the air at the bo...

Страница 11: ...pair Sand and other abrasive substances cause premature wear and the reduction of pump performance Work on the electrical components of the pump may be performed exclusively by authorised agent this a...

Страница 12: ...is clogged Clean Check the power source Pull the power plug out of the electrical socket and clean the impeller Make sure that the permitted highest temperature limit of 35 C is not exceeded Check the...

Страница 13: ...13 400W AUTOMATIC STAINLESS STEEL SUBMERSIBLE CLEAN WATER PUMP...

Страница 14: ...14 400W AUTOMATIC STAINLESS STEEL SUBMERSIBLE CLEAN WATER PUMP...

Страница 15: ...rsible Water Pump Complies with the essential health and safety requirements of the following directives 89 336 EEC EMC Directive 73 23 EEC 93 68 EEC Low Voltage Directive Standards and technical spec...

Страница 16: ......

Отзывы: