5.6.
Showing and teaching the end user about the maintenance and
adjustment procedures of the burner
It is necessary to show and teach the end user the maintenance procedures
for operating the burner efficiently and keep its reliability in high degree order.
Also the installer should demonstrate and teach the end user how to adjust the
thermal capacity of the burner, according to the estimated heat consumption and
initial fuel transport auger charging:
•
combustion chamber cleaning
– it is recommended (at least once per
day or a longer period is appropriate) to stop the burner (turn off the
“START” signal of the burner), wait until the char has been incinerated
and the burner cooled down. After the combustion chamber has been
cooled down, remove the grate and clean the ash residue thoroughly.
Use protective gloves and appropriate instruments if necessary;
•
cleaning procedure of the flexible hose, connecting the fuel
transport auger and the main unit of the burner
– it is recommended
to clean periodically this hose, as during the fuel transport fine particles
are deposited on the internal surface of the hose, which eventually
could impede the fuel transport though it. Furthermore, the deposited
layer of fine fuel particles could be ignited in case that hot flue gases
are exhausted though this hose in case of emergency;
ATTENTION :
regular cleaning of burner will ensure long-life reliable
exploitation period, economic and efficient performance of the unit;
5.7.
Safety and unexpected risks
Risks could arise at the exploitation of the burner:
The automatic pellet burner “ERATO GP20+” is designed according to the
safety requirements of the operating European standards and norms. However
safety and unexpected risks could arise in situations like following:
•
The pellet burner is operating incorrectly/abnormally;
•
The unit is installed by unauthorized/unqualified personal;
•
The safety instructions, described in this manual are not followed and
fulfilled;
Unexpected risks:
The unit is designed and produced according to the requirements of the
operating EU safety norms. However, in spite of that possible risks are